PSEN cs6.2p
Operating Manual PSEN cs6.2p
1003430-EN-06
| 13
Lateral and vertical offset
Lateral offset when aligning to the triangle or square marking
Alignment 1: Actuator PSEN cs6.1 aligned
to the square marking on the switch
Alignment 2: Actuator PSEN cs6.1 aligned
to the triangle marking on the switch
[1]
[2]
[3]
[4]
[4]
[5]
[6]
4
0
14
-12 -8 -4
0
12
8
4
8
4
0
12
14
[7]
4
14
[1]
[2]
[3]
[4]
[4]
[5]
[6]
-8 -4
0
8
4
8
4
0
12
-12
12
[7]
12
8
4
0
12
Alignment 1: Actuator PSEN cs6.1 low pro-
file glue or PSEN cs6.1 low profile screw
aligned to the square marking on the switch
Alignment 2: Actuator PSEN cs6.1 low pro-
file glue or PSEN cs6.1 low profile screw
aligned to the triangle marking on the
switch
0
12
0
12
0
-12
12
[2]
[1]
[3]
[5]
[4]
[4]
[7]
[6]
Actuator PSEN cs6.1 low profile glue or PSEN
cs6.1 low profile screw to triangle marking is
not suitable because the operating distances
are too low.
Legend
[1] Hysteresis
[2] Typical operating distance S
O
[3] Typical release distance S
r
[4] Offset in mm
[5] Operating distance in mm
[6] Response range
[7] Status of LED