background image

PNOZ mc10p

Operating Manual 1002696-EN-02

}

Configurable safety systems PNOZmulti

Summary of Contents for PNOZ mc10p

Page 1: ...PNOZ mc10p Operating Manual 1002696 EN 02 Configurable safety systems PNOZmulti...

Page 2: ...umentation will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Interne...

Page 3: ...r safety 9 Section 4 Function description 10 4 1 Functions 10 4 2 Input and output data 10 4 3 Assigning the inputs outputs in the PNOZmulti Configurator to the sercos III inputs outputs 11 4 4 Block...

Page 4: ...is particularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates prevent...

Page 5: ...Introduction Operating Manual PNOZ mc10p 1002696 EN 02 5 INFORMATION This gives advice on applications and provides information on special fea tures...

Page 6: ...d for errors Delivery configuration with IP address 192 168 1 64 and Sercos address 64 24 virtual inputs and outputs on the control system PNOZmulti can be defined in the PNOZmulti Configurator for co...

Page 7: ...Overview Operating Manual PNOZ mc10p 1002696 EN 02 7 Legend X1 X2 sercos III interfaces LED LINK ACT1 LINK ACT2 PWR S3...

Page 8: ...lti System Expansion for details of the base units that can be connected The configurable small control systems PNOZmulti are used for the safety related interrup tion of safety circuits and are desig...

Page 9: ...d liability All claims to warranty and liability will be rendered invalid if The product was used contrary to the purpose for which it is intended Damage can be attributed to not having followed the g...

Page 10: ...iguration is described in detail in the PNOZmulti Configurator s online help 4 2 Input and output data The data is structured as follows Input area The inputs are defined in the master and transferred...

Page 11: ...I7 i8 i15 i16 i23 Input data sercos III Byte 0 Bits 0 7 Byte 1 Bits 0 7 Byte 2 Bits 0 7 Virtual outputs on PNOZmulti Configurator o0 o7 o8 o15 o16 o23 Output data sercos III Byte 0 Bits 0 7 Byte 1 Bi...

Page 12: ...g rail in an upright position so that the earthing springs on the control system are pressed on to the mounting rail The ambient temperature of the PNOZmulti units in the control cabinet must not exce...

Page 13: ...of 1 PNOZ mc10p to the left of the base unit Connect the base unit and the expansion module as described in the operating instructions for the base units Do not connect a terminator to the last expan...

Page 14: ...nnection cable and connector must be met Only use standard industrial Ethernet cable and connectors Only use double shielded twisted pair cable and shielded RJ45 connectors indus trial connectors 100B...

Page 15: ...d to the system the project must be amended using the PNOZmulti Configurator Proceed as described in the operat ing instructions for the base unit NOTICE For the commissioning and after every program...

Page 16: ...module PNOZ mc10p is configured and started automatically The LED S3 displays the status of PNOZ mc10p at sercos III 7 1 Messages Legend LED on LED flashes LED off LED Meaning PWR Supply voltage is pr...

Page 17: ...long CP3 communication phase 3 is active green CP4 communication phase 4 is active green RT status switches from fast forward to loopback red orange Application error see GDP FSP Status Codes Class E...

Page 18: ...Times Supply interruption before de energisation 20 ms Environmental data Ambient temperature In accordance with the standard EN 60068 2 14 Temperature range 0 60 C Storage temperature In accordance...

Page 19: ...tion type In accordance with the standard EN 60529 Mounting area e g control cabinet IP54 Housing IP20 Terminals IP20 Mechanical data Mounting position Horizontal on top hat rail DIN rail Top hat rail...

Page 20: ...1002696 EN 02 20 9 Order reference Order reference Product type Features Order no PNOZ mc10p Fieldbus module sercos III 773 715 Terminator jumper Product type Features Order no PNOZmulti bus terminat...

Page 21: ...p ThE SPIrIT Of SAfETY are registered and protected trademarks of Pilz Gmbh Co KG in some countries We would point out that product features may vary from the details stated in this document dependin...

Reviews: