Overview
Operating Manual PNOZ m ES CANopen
1002699-EN-06
7
2
Overview
2.1
Scope of supply
}
Expansion module PNOZ m ES CANopen
}
Jumper
2.2
Unit features
Using the product PNOZ m ES CANopen:
Expansion module for connection to a base unit from the configurable control system
PNOZmulti 2 .
The product has the following features:
}
Can be configured in the PNOZmulti Configurator
}
Connection for CANopen
}
Station addresses from 0 ... 99, selected via rotary switch
}
Transmission rate selected via rotary switch (1 MBit/s, 10 kbit/s, 125 kBit/s, 20 kbit/s,
250 kBit/s, 50 kbit/s, 500 kBit/s, 800 kbit/s)
}
Status indicators for communication with CANopen and for errors
}
128 virtual inputs and outputs on the control system PNOZmulti 2 can be defined in the
PNOZmulti Configurator for communication with the fieldbus CANopen.
}
Max. 1 PNOZ m ES CANopen can be connected to the base unit
}
Plug-in connection terminals:
either spring-loaded terminal or screw terminal available as an accessory (see order
reference)
}
For details of the PNOZmulti 2 base units that can be connected, please refer to the
document "PNOZmulti System Expansion".