Function description
Operating Manual PNOZ s30
1001715-EN-15
26
4.4.3
Basic configuration
Two basic configurations are available for standard applications, for simple configuration
within the display menu. A basic configuration contains limited menu functions adapted for
standard applications, with partly pre-defined parameters.
The following basic configurations are available:
Basic configuration 1:
Ini pnp pnp (proximity switch)
Pre-defined settings and configuration options:
}
Encoder type
2 pnp type proximity switches
}
Switch functions
–
Standstill (F1)
– Standstill frequency configurable in Hz
–
Speed (F2)
– Max. frequency (v max) configurable in Hz
}
Parameter set/select input
P0, select inputs are ignored ("None" mode")
}
Hysteresis
Standstill and speed, 2 % each
}
Output assignment
–
Standstill: Relay output Rel. 1 and semiconductor output Out 1
–
Speed: Relay output Rel. 2 and semiconductor output Out 2
}
Reset mode
–
Rel. 1, Rel. 2 Out 1, Out 2: Automatic reset
}
Switch delay
None
}
Max. encoder frequency
3.5 kHz
Basic configuration 2:
Rotary encoder
}
Encoder type
Rotary encoders
–
Rotary encoder type configurable
}
Switch functions
–
Standstill (F1)
– Standstill frequency configurable in Hz
–
Speed (F2)
– Max. frequency (v max) configurable in Hz