Wiring
Operating Manual PSEN sc M 3/5 series
1005055-EN-02
| 56
6.6
Connections for muting sensors
Wire the muting sensors as shown in the following diagrams.
Muting 1
Muting 2
Muting 1
Muting 2
24 V
24 V
24 V
24 V
Muting sensor
Safety laser scanner
Configurable input or input/output
8-pin connection:
12-pin connection:
Configurable input or input/output
3, 7, 9, 10, 11
3, 4, 1
Configurable input or input/output
Configurable input or input/output
Fig.: Wiring of 4 muting sensors on the master unit
Muting 1
Muting 2
24 V
24 V
Muting sensor
Safety laser scanner
Configurable input or input/output
8-pin connection:
12-pin connection:
Configurable input or input/output
3, 7, 9, 10, 11
3, 4, 1
Fig.: Wiring of 2 muting sensors on the master unit