PSEN opII4F Series
Operating Manual PSEN opII4F Series
1003502-EN-09
| 64
Appendix
Check list
The checklist below is intended as an aid in for the following work on a safety light curtain
of PSEN opII4F Series:
}
commissioning,
}
recommissioning, and
}
running the specified regular check.
Note that the check list is not intended to replace the plant-specific safety analysis required
for commissioning/recommissioning, nor the resulting inspections and actions.
INFORMATION
Commissioning, recommissioning and regular inspection may only be car-
ried out by qualified personnel.
We recommend that you keep the completed check list and store it with the machine docu-
mentation for reference.
No. Action
OK
NOT OK Notes
1
Check the category/standards
Does the category of the safety light curtain
match the category required for the plant/
machine?
Have the standards applicable for the plant/
machine been considered?
2
Check the safety light curtain ambient
conditions
Have the environmental conditions been
met (see
Have the technical details been met for all
the safety light curtain components?
3
Check access to the danger zone
Are all access points to the danger zone
safeguarded either by safety light curtains
or by mechanical safeguards?
4
Check minimum distance to danger zone
Has the minimum distance been calculated
in accordance with the applicable stand-
ards?
Has the minimum distance been determined
with the response time according to the
beam coding (see
Has the calculated minimum distance been
maintained at all points?