PSEN opII4H Series
Operating Manual PSEN opII4H Series
1003501-EN-08
| 58
Mechanical data
632069
632070
632071
Max. torque setting
Clamping screw
1,1 Nm
1,1 Nm
1,1 Nm
Installation screw
3 Nm
3 Nm
3 Nm
Fixing screw
0,7 Nm
0,7 Nm
0,7 Nm
Dimensions
Height
1.504 mm
1.654 mm
1.804 mm
Width
35 mm
35 mm
35 mm
Depth
40 mm
40 mm
40 mm
Weight
4.250 g
4.655 g
5.060 g
Where standards are undated, the 2015-12 latest editions shall apply.
Classification according to ZVEI, CB24I
The following tables describe the classes and specific values of the product interface and
the classes of interfaces compatible with it. The classification is described in the ZVEI posi-
tion paper "Classification of Binary 24 V Interfaces - Functional Safety aspects covered by
dynamic testing".
Safe 1-pole HL outputs
Source
Drain
Safety switch
C2
Evaluation device
C1, C2
Source parameters
Min.
Typ.
Max.
Test impulse duration
-
-
300 µs
Rated current
-
-
0,1 A
Capacitive load
-
-
40 nF