Attach the safety light curtain to the mounting surface
[2]
[3]
[1]
Please note the following when installing the
safety light curtain [1]:
If the standard installation kit is used, the gap [2]
between the safety light curtain [1] and the installation
surface [3] must be smaller than the safety light curtain
resolution.
Prepare the installation surface.
Clean the installation surface. The installation surface must be free of dust and grease.
[1]
[1]
[2]
Mount the holder on the end cap on the connec-
tion side of the safety light curtain
Feed the cable [2] through the opening in the holder.
Ensure that the holder is flush with the end cap (see
diagram).
Attach the holder to the end cap with the tightening
screws (Torx T10) included in delivery.
[1] Torque setting 0,7 Nm