Function description
Operating Manual PSEN ml sa 1.1/2.1/2.2, PSEN ml DHM
1005457-EN-02
| 26
INFORMATION
If guard locking is deactivated using the escape release, there is a low sig-
nal at safety outputs 12 and 22. A warning will be output (see
not
switch to the fault condi-
tion.
Mode of operation
In the danger zone, if the button of the escape release pin is pressed towards the safety
gate, the escape release impacts directly on the auxiliary release of the safety switch and
the auxiliary release unlocks the safety gate. The safety gate can be opened immediately,
enabling the operator to leave the danger zone.
There is a low signal at safety outputs 12 and 22 if the escape release was operated.
4.9.1
Recommissioning
1. Pull back the button of the escape release pin.
2. Acknowledge the stop signal in the controller.
3. Carry out a function test using the escape release. The safety function may only be
checked by qualified personnel.