PSEN cs6.11n
Operating Manual PSEN cs6.11n
1004127-EN-03
20
Normal mode
LED status
Switch status
Device
green
Ready for operation
Safety gate
yel-
low
Actuator is within the response range
Off
Actuator is outside the response range
Input
yel-
low
The unit is ready for operation
LED display actuator teach-in
LED status
Switch status
Remedy / measure
Device
Safety Gate
Input
Green
yellow
Display not
definitive
Teaching actuator.
Duration approx. 20
seconds
-
Green
yellow
Display not
definitive
Actuator teach-in com-
plete.
Switch voltage off
and then on again.
Error display
LED status
Switch status
Remedy / measure
Device
Safety Gate
Input
red
Off
Off
Internal error on
switch
Change the switch.
red
yellow
yellow
Supply voltage is
outside the toler-
ance range
Ensure the voltage supply
corresponds to the
.
yellow
Display not
definitive
Display not
definitive
Supply voltage is at
the limit of the toler-
ance range
Ensure the voltage supply
corresponds to the
.
red
Display of
last status
Display of
last status
Outputs in fault con-
dition
Check the outputs and
switch the voltage off and
then on again.
green
yellow
Display not
definitive
Wrong actuator
Use the actuator PSEN
cs6.11 M12.