PSEN cs5.1 M12/8
Operating Manual PSEN cs5.1 M12/8
1003419-EN-06
9
}
Safety Device Diagnostics (SDD)
–
Safety Device Diagnostics can be used to poll sensor information, to perform ac-
tions and to read configuration parameters
–
Manipulation protection in accordance with ISO 14119 (chap. 7.2.d) is possible by
verifying the short name of the actuator through the controller via SDD communica-
tion
}
Diagnostic input for Y1 for Safety Device Diagnostics (SDD)
}
Signal output/diagnostic output Y32 for Safety Device Diagnostics
}
LED display for:
–
State of the actuator
–
State of the inputs
–
Supply voltage/fault
}
4 actuation directions, each with 3 approach directions (see
markings [
–
Square marking for normal operating distance
–
Triangle marking for short operating distance
–
2 semicircle markings for a lateral approach. Please note the Lateral and vertical
offset with the lateral approach to the semicircle marking.
The guaranteed safe operating distances for the specified selections only apply when
the actuator approaches the switch vertically. With the other approach directions, the
operating distances may sometimes be considerably larger (particularly when ap-
proaching the semicircle).
Function description
The safety outputs may have a high or low signal, depending on the position of the actuator
and the signal status of the safety inputs.
Electrical states of the safety inputs and outputs (when switch is ready for operation:
DEVICE LED is green):
Actuator in
the re-
sponse
range
Safety input
S11
Safety input
S21
Safety out-
put 12
Safety out-
put 22
Signal out-
put Y32
(without use
of the SDD)
Yes
High
High
High
High
High
Yes
Low
Low
Low
Low
High
No
x
x
Low
Low
Low
Yes
High
Low
High
Low
High
Yes
Low
High
Low
High
High
x: High or low signal