PSEN cs5.1 M12/8
Operating Manual PSEN cs5.1 M12/8
1003419-EN-06
11
}
With Safety Device Diagnostics there are the following diagnostic options for the field-
bus module:
–
Poll information of the sensors (examples: what sensor in the series has switched,
at what point could there be an open circuit in the series connection)
–
Read configuration parameters of the sensors (examples: Number of remaining
teach-in processes, serial number of the switch)
–
Perform actions (example: poll updated actuator name)
The results of the sensor diagnostics can be checked already during the installation phase
via the display in the fieldbus module, without the need to connect the fieldbus module to
the network.
}
With Safety Device Diagnostics there are the following diagnostic options for the field-
bus module for simple wiring:
–
Information is passed on via the fieldbus module directly to the network
–
Mappings of the signal outputs to the sensor are automated by the SDD.
This prevents wiring errors and an expansion or reduction of the sensors is possible
without the need to change existing wiring.
–
Wiring in accordance with IP20: Rapid installation in the control cabined is enabled.
–
Wiring in accordance with IP67: Various passive junctions can be used (see
) to connect several sensors with only one
cable from the field in the control cabinet.
Further information on Safety Device Diagnostics can be found in
Operating distances
Alignment of the actuator
Operating distances
[1]
[1] Actuator aligned to the square marking on the
switch
S
ao
Assured operating distance: 8 mm
S
ar
Assured release distance: 20 mm
S
o
Typical operating distance: 11 mm
S
r
Typical release distance: 14 mm