PSEN cs4.1n
Operating Manual PSEN cs4.1n
22180-EN-06
| 17
Procedure actuator PSEN cs2.1:
1. Use permanently secured M5 safety screws with a flat head (e.g. M5 cheese-head or
pan head screws).
Provide the mounting surface with two drill holes for the screw connection of the actu-
ator (see
).
2. Use two screws to fix the actuator in place. Align the actuator and tighten the screws.
Actuator cs3.1 low profile
WARNING!
Loss of the manipulation protection by inadequate environmental con-
ditions
The loss of the manipulation protection can allow manipulation of the inter-
locking device and it may lead to serious injury or death.
– Make sure that the actuator has no direct or repetitive contact with
materials such as methyl ethyl ketone (MEK), petrol or isopropanol.
}
The actuator is secured against unauthorised removal, and against contamination by the
sealing. The seal should be regarded as equivalent to using permanent fastenings in ac-
cordance with EN ISO 14119.
}
By removing the actuator, the actuator will be destroyed.
}
The actuator’s adhesive force on the materials aluminium, stainless steel, polycarbonate
and glass was checked. For deviating surface materials check the adhesive force on the
surface.
}
After a cure time of 24 hours, 90 % of the final adhesive force are achieved. The harden-
ing must take place at min. 20 °C. With lower temperatures the cure time is clearly exten-
ded.
}
No continuous force must affect the actuator.