PSEN ma1.3a/b-20

Operating Manual-21705-EN-11

}

PSEN sensor technology

Summary of Contents for 506 220

Page 1: ...PSEN ma1 3a b 20 Operating Manual 21705 EN 11 PSEN sensor technology...

Page 2: ...nta tion will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Internet...

Page 3: ...osal 6 For your safety 6 Unit features 7 Function description 7 Block diagram 7 Operating distances 8 Lateral and vertical offset 8 Wiring 10 Pin assignment 11 Requirements and connection to evaluatio...

Page 4: ...is particularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates prevent...

Page 5: ...tside the technical details see Technical details 18 NOTICE EMC compliant electrical installation The product is designed for use in an industrial environment The product may cause interference if ins...

Page 6: ...nd liability will be rendered invalid if The product was used contrary to the purpose for which it is intended Damage can be attributed to not having followed the guidelines in the manual Operating pe...

Page 7: ...with square design PSEN ma1 3 12 various directions of actuation pos sible Operation Magnetic Switching voltage 24 VDC LED to display switch status Function description If the actuator is within the r...

Page 8: ...ff Legend Sao Assured operating distance Somin Min operating distance Sar Assured release distance The offset independent values for the switching distances are included in the Technical details 18 La...

Page 9: ...0 5 5 2 7 0 6 0 4 0 4 6 0 5 0 3 0 The stated values are valid at a temperature of 20 C Actuator PSEN ma1 3 12 2 1 3 Legend 1 Lateral offset 2 Vertical offset 3 Sensing face Assured operating distance...

Page 10: ...tance see evaluation device s technical details Ri Internal resistance sensor see Technical details 18 Rl km Cable resistance km of the cable see technical details cable Ensure the wiring and EMC requ...

Page 11: ...cannot be connected in series may not be used for safety circuits Requirements and connection to evaluation devices For use of PSEN ma1 3a b 20 in accordance with DIN EN 60947 5 3 an evaluation devic...

Page 12: ...in the operating manual for the selected evaluation device Defined properties of evaluation devices 2 channel with feasibility monitoring Open circuit monitoring of the safety switch is performed Inp...

Page 13: ...aluation device Examples for connection to Pilz evaluation devices 1 2 3 4 5 6 S21 S22 S11 S12 PNOZ s3 PSENmag brown white blue black PNOZmulti PSENmag T0 I0 T1 I1 1 2 3 4 5 6 brown white blue black A...

Page 14: ...al Please check the operating distances and the assured release dis tance CAUTION Possible loss of the safety function by changing the release distance Sar with non flush installation Installing the s...

Page 15: ...le manner must be preven ted Please note the installation measures in accordance with EN ISO 14119 for a proximity switch type 4 with coding level Low Alignment errors of the guard must not adversely...

Page 16: ...ecial threads Note the max torque setting see Technical details 18 Installation with actuator PSEN ma1 3 12 Attach the bracket using countersunk screws M4 Sensing face The sensing face at the actuator...

Page 17: ...s see Technical details 18 only apply when the safety switch and actuator are installed according to the specifications Installation 14 Operating distances may deviate if other arrangements are used N...

Page 18: ...sted Sensor s mode of operation Magnetic Magnetic Coding level in accordance with EN ISO 14119 Low Low Design in accordance with EN ISO 14119 4 4 Classification in accordance with EN 60947 5 3 PDDB PD...

Page 19: ...tude 1 mm 1 mm Shock stress Acceleration 30g 30g Duration 11 ms 11 ms Airgap creepage Pollution degree 3 3 Rated insulation voltage 250 V 250 V Rated impulse withstand voltage 4 kV 4 kV Protection typ...

Page 20: ...222 506232 General 506222 506232 Certifications CE EAC Eurasian ECOLAB T V cULus Listed CE EAC Eurasian ECOLAB T V UL cUL cULus Listed Sensor s mode of operation Magnetic Magnetic Coding level in acco...

Page 21: ...ation 30g 30g Duration 11 ms 11 ms Airgap creepage Pollution degree 3 3 Rated insulation voltage 250 V 250 V Rated impulse withstand voltage 4 kV 4 kV Protection type Housing IP67 IP67 Mechanical data...

Page 22: ...chieve the required safety level for your plant machine B10d in accordance with EN ISO 13849 1 2015 and EN 62061 TM year in accordance with EN ISO 13849 1 2015 7 300 000 20 Order reference System Prod...

Page 23: ...istance 12 mm 516 130 Accessories Product type Features Connector X1 Connector X2 Connector X3 Order no PSEN PDP67 M12 8sm screw ter minals Connector with screw terminals M12 8 pin male con nector str...

Page 24: ...yNET p THE SPIRIT OF SAFETY are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document depe...