background image

PIT es Set10u-5c PCB

Operating Manual-1004385-EN-03

}

Control and signal devices

Summary of Contents for 400 460

Page 1: ...PIT es Set10u 5c PCB Operating Manual 1004385 EN 03 Control and signal devices...

Page 2: ...nta tion will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Internet...

Page 3: ...el 10 Warranty and liability 11 Disposal 11 For your safety 11 Block diagram terminal configuration 12 Function description 12 Operating states 12 Installation 13 Wiring 16 Preparing for operation 16...

Page 4: ...Contents Operating Manual PIT es Set10u 5c PCB 1004385 EN 03 4 Accessories 27 EC declaration of conformity 27...

Page 5: ...n that is particularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates...

Page 6: ...60204 1 EN ISO 13849 EN ISO 13850 and EN 60947 5 5 contacts in accordance with EN 60947 5 1 Clear visual display when E STOP function is active In inactive state the E STOP pushbutton is not lit and...

Page 7: ...ontact block bracket Order No 400 331 5 2 contact blocks PIT es2c Order No 400 321 6 3 cables for connecting the LED safety printed circuit board with the contact blocks included in Order No 400 342 7...

Page 8: ...s Set10u 5c PCB Operating Manual PIT es Set10u 5c PCB 1004385 EN 03 8 Marking on E STOP pushbutton 9 1a 1b 1c 1d Legend 1a Order number 1b Date of manufacture mmyy 1c Batch number 1d Address Pilz home...

Page 9: ...d the voltage to the evaluation device is interrupted single channel par tially operated CAUTION It must not be possible to defeat the E STOP pushbuttons Otherwise ma terial damage and severe injuries...

Page 10: ...ver this does not guarantee the functional safety of the overall plant machine In order to achieve the re quired safety level for the overall plant machine define the safety requirements for the plant...

Page 11: ...has been made e g exchanging components on the PCB boards soldering work etc Disposal In safety related applications please comply with the mission time TM in the safety related characteristic data Wh...

Page 12: ...ction is inactive when the connections X1 1 and X4 2 are disconnected from the supply The lighting goes out the E STOP device is without function The E STOP device detects whether the red lighting is...

Page 13: ...to ensure a tight seal The unit is an installation unit the LED safety printed circuit board and the contact blocks must be installed in a mounting area IP54 the actuation side of the emergency stop...

Page 14: ...n 1 the plug in connection is reverse polarity protected Insert the E STOP pushbutton 1 into the opening of the mounting plate Route the three core connection cable 7 to the opening for the lighting c...

Page 15: ...s not twist when fixing to prevent damage of the connection cable 7 Only the plastic nut supplied 3 must be used for fixing the LED safety cir cuit board 2 Plug the pre installed contact blocks 5 with...

Page 16: ...the chain before the PIT es Set10u 5c PCB the PIT es Set10u 5c PCB is not electrically supplied and therefore it is not illuminated Preparing for operation Connect the socket X3 9 on the LED safety p...

Page 17: ...1 Pin 1 1 1 1 1 1 Pi Pi 1 1 Pi X5 X5 X4 Pi a b c X2 8 Legend a Grey Connection X4 2 with X2 3 b White Connection X5 2 with X2 2 c Yellow Connection X5 1 with X1 2 NOTICE Check the function of the emer...

Page 18: ...channel of the input circuit is open Detection of shorts across contacts and earth fault detection Detection of shorts across contacts is possible also via a positive and negative input circuit Digit...

Page 19: ...unction Ensuring that the red lighting can be detected under defined environmental con ditions If terminal X1 1 is transposed with X1 2 when connecting the LED safety printed circuit board the opening...

Page 20: ...ce channel 1 Input on the evaluation device channel 1 Grey White Yellow Fig Connection example flashing function is active X1 1 X1 2 X2 1 X3 X2 X2 2 X2 3 2 1 X4 2 1 X5 LED safety printed circuit board...

Page 21: ...is re quired Output of the con tact block X5 2 white cable If a flashing func tion is not required Con nection to 24 V e g X1 1 or external supply IMx Ix controller input 1 S12 X2 3 Input for input c...

Page 22: ...ted circuit board Contact blocks NOTICE Check wiring Check the function of the E STOP pushbutton before commissioning the plant machine by interrupting the GND connection of the LED safety printed cir...

Page 23: ...enance During operation the light sources lose brightness The device is equipped with sufficient brightness for a service life of 20 years Check at regular intervals whether the lighting of the E STOP...

Page 24: ...ion category In accordance with the standard EN 60947 5 1 DC13 at 24 V Current 0 3 A Conventional thermal current 0 3 A Contact fuse protection blow out fuse quick 1 A Contact material AgNi Mechanical...

Page 25: ...to achieve the required safety level for your plant machine Operating mode EN ISO 13849 1 2015 EN ISO 13849 1 2015 EN ISO 13849 1 2015 PFHD 1 h EN ISO 13849 1 2015 TM year Perceptibility of red illum...

Page 26: ...ion s SIL PL values Supplementary data Permitted operating height The values stated in the technical details apply to the use of the device in operating heights up to max 2000 m above sea level When u...

Page 27: ...board Product type Features Order no PIT EF LED 1 PCB LED safety printed circuit board for PIT es10u 400 342 Contact block and bracket Product type Features Order no PIT esc2c 1 N C spring loaded ter...

Reviews: