Pilz 328 301 Operating Manual Download Page 1

PSS u2 ES 8DI

Operating Manual-1003610-EN-01

}

Control system PSS u2

}

Remote I/O system PSS u2

Summary of Contents for 328 301

Page 1: ...PSS u2 ES 8DI Operating Manual 1003610 EN 01 Control system PSS u2 Remote I O system PSS u2...

Page 2: ...umentation will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Interne...

Page 3: ...4 3 Inputs 9 4 4 Reaction times 13 4 5 Energy saving functions 13 Section 5 Address assignment 14 Section 6 Installation 15 6 1 General installation guidelines 15 6 1 1 Dimensions 15 6 2 Inserting and...

Page 4: ...as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive measures that can be taken WARNING T...

Page 5: ...Introduction Operating Manual PSS u2 ES 8DI 1003610 EN 01 5 INFORMATION This gives advice on applications and provides information on special fea tures...

Page 6: ...nit for the electronic modules The terminal block is plugged into the electronic modules and is used to connect the field wiring Details of the terminal blocks that can be used are available under Int...

Page 7: ...INFORMATION The module is supported by PASconfig from Version 1 0 0 We recommend that you always use the latest version download from www pilz com 3 3 Safety regulations 3 3 1 Use of qualified personn...

Page 8: ...it is intended Damage can be attributed to not having followed the guidelines in the manual Operating personnel are not suitably qualified Any type of modification has been made e g exchanging compone...

Page 9: ...configurable software filter Pulse stretching can be configured for the inputs Any signals that are shorter than the signal suppression time tpulse_sup are filtered out The signal suppression time de...

Page 10: ...at the input in order to be de tected Pulse stretching The module stretches a 1 signal or 0 signal at the input terminals to the configured pulse stretch time tstretch If the signal is longer than th...

Page 11: ...al after pulse stretching has elapsed 1 signal at the terminal after pulse stretching has elapsed 0 signal at the terminal after pulse stretching has elapsed Fig States for pulse stretching stretch l...

Page 12: ...ulse stretching Pulse stretching Stretched signal Stretched signal t1 signal Duration of 1 signal tstretch Duration of pulse stretching tsignal_min Time for which a signal must be present at the input...

Page 13: ...that are not detected during stretching 4 4 Reaction times You can find information about the reaction times in the operating manual for the head module PSS u2 P0 F S PN 4 5 Energy saving functions Th...

Page 14: ...e module occupies 1 Byte in the process image of inputs PII Meaning State Bit 0 Input data I0 0 0 signal 0 V at the input 1 1 signal 24 V at the input Bit 1 Input data I1 Bit 2 Input data I2 Bit 3 Inp...

Page 15: ...arge can damage components Ensure against discharge before touching the product e g by touching an earthed conductive sur face or by wearing an earthed armband 6 1 1 Dimensions The dimensions include...

Page 16: ...ctronic modules may only be plugged or unplugged if the terminal block has been removed first The mechanics of the electronic modules are designed for 20 plug in out cycles 6 2 1 Inserting an electron...

Page 17: ...Installation Operating Manual PSS u2 ES 8DI 1003610 EN 01 17 3 Insert the terminal block into the suspen sion lug on the module 4 Press the terminal block downwards until you hear it click into place...

Page 18: ...c module can be hot swapped Effects Module bus communication between the other modules is not interrupted The configuration data is retained The module is detected automatically as soon as the module...

Page 19: ...lat head screwdriver Strip the wire back 9 mm Feed the stripped cable as far as it will go into the opening for the spring loaded ter minal Check that the cable is firmly seated Please note The minimu...

Page 20: ...minal configuration Connection example 1 Input I0 3 Input I1 5 Input I2 7 Input I3 9 Input I4 11 Input I5 13 Input I6 15 Input I7 1 channel sensor Sensors supplied via the 24 V periphery supply from t...

Page 21: ...ur 2 Meaning Further informa tion Module not ready for operation Green Module ready for operation Green Green Module in operation and there is a 1 signal at the input Green Module in operation and the...

Page 22: ...lue the module sends an all clear Too hot If the module temperature exceeds another threshold value then an error message is sent to the head module the inputs continue to be read and appear in the ST...

Page 23: ...nges from 1 to 0 0 3 ms Max processing time of input when signal changes from 0 to 1 0 3 ms Min processing time of input when signal changes from 1 to 0 0 005 ms Min processing time of input when sign...

Page 24: ...EN 61131 2 UL IEC 61010 2 201 Overvoltage category II Pollution degree 2 Protection type In accordance with the standard EN 60529 Mounting area e g control cabinet IP54 Housing IP20 Potential isolatio...

Page 25: ...odule Product type Features Order No PSS u2 A LC E1 10 pcs Label holder 23 5 x 10 5 mm 10 pieces 328 910 PSS u2 A LC E2 10 pcs Label holder 103 x 10 5 mm 10 pieces 328 911 PSS u2 A LA E1 10 pcs Labell...

Page 26: ...p ThE SPIrIT Of SAfETY are registered and protected trademarks of Pilz Gmbh Co KG in some countries We would point out that product features may vary from the details stated in this document dependin...