Generator 1 Off
3-15-12
continued
2.
GEN 1 switch..............................
RESET then ON
If GEN 1 does not reset:
3.
Aircraft.........................................
At pilots discretion, continue flight without
the services of the load shed systems
and buses
CAUTION
The following buses are automatically load shed (no additional Cautions will
be shown) and the systems connected to them will be inoperative:
−
Generator 1 bus (Left rear CB panel)
−
Non Essential Bus (Right front CB panel)
−
Cabin bus (Right rear CB panel)
CAUTION
The following high current consumption systems are automatically load
shed:
−
Cabin heater
−
Under floor heater
−
VCCS compressor
−
Footwarmer (optional system)
−
Logo lights (optional system)
---------- END -----------
Generator 2 Off
3-15-13
Generator 2 is OFF line and engine running.
1.
Systems MFD - ELECTRICAL
window........................................
Confirm the failure
2.
GEN 2 switch..............................
RESET then ON
If GEN 2 does not reset:
3.
Aircraft.........................................
At pilots discretion, continue flight without
the services of the load shed systems
and buses
Continued on next page