![Pike Evolution PT4+ Operator'S Manual Download Page 24](http://html1.mh-extra.com/html/pike/evolution-pt4/evolution-pt4_operators-manual_1555979024.webp)
22
Text display
The text display at the
bottom of the control panel
shows a continual count
of the elapsed time for the
current signal of the active
phase. In error situations,
this display is used to
provide alphanumeric status codes, as follows:
Low Battery
Battery voltage becoming too low.
Batt Fail
Insufficient battery voltage to continue.
Red Fault
The red vehicle aspect failed to turn on or off.
Amber Fault
The amber vehicle aspect failed to turn on or
off.
Green Fault
The green vehicle aspect failed to turn on or
off.
Red Man Fault
The red man pedestrian aspect failed to turn
on or off.
Grn Man Fault
The green man pedestrian aspect failed to
turn on or off.
Wait Fault
The wait aspect failed to turn on or off.
Tactile Fault
The tactile aspect failed to turn off.
Error 010
Invalid configuration data.
Error 011
Failed to communicate with configuration
plug.
Error 012
Incompatible software installed.
Error 013
Controller started following a watchdog reset.
Coms Recovry nnn
Recovering from comms loss (10 minute period).
Comms Fail
Sustained communications fault.
Config Error 01
Insufficient battery voltage.
Config Error 02
Duplicate serial number.
Config Error 03
Invalid operational mode.
Config Error 04
Language mismatch.
Config Error 05
Software mismatch.
Config Error 06
Nearside/farside mismatch.
Config Error 07
Configuration incompatible with XL2 slaves.
Config Error 10
Master has unconfigured vehicle head.
Config Error 11
Master has unconfigured pedestrian head.
Config Error 12
A slave has unconfigured pedestrian head.
Config Error 13
A slave has unconfigured vehicle head.
Config Error 20
No vehicle phases configured.
Config Error 21
No pedestrian phases configured.
Config Error 30
Awaiting confirmation of radio channel.
Config Error 31
Awaiting confirmation of authority mode.
Config Error 32
Awaiting confirmation of slave identity.
Config Error 40
No head detected.
Config Error 50
Engineers terminal interlocking active.
Config Error 99
Internal error.
Veh Fail nn
Could not find a slave for phase nn.
Ped Fail nn
Could not find a slave for pedestrian phase
nn.
Batt Fail nn
Critical battery voltage on slave nn.
Lamp Fault
The amber or green vehicle aspect failed to
turn on or off.
Stopped
System has stopped due to CAT1 fault.
Green Conflict
Green or green man aspect was on
unexpectedly.
Error 020
Local monitor fault (whilst lamp was on).
Error 021
Local monitor fault (whilst lamp was off).
Error 022
Local lamp conflict detected on disused
head.
Error 023
Local lamp conflict detected by CPLD.
Error 024
Local CPLD watchdog fault.
Error 025
Local front panel fault.
Error 030
Master detected invalid broadcast.
Error 031
Master detected aspects are not set as
requested.
Error 032
Master detected invalid response from slave.
Error 040
Master has been notified of CAT1 fault on
slave.
Error 041
Master has been notified of invalid broadcast
on slave.