![Pike Evolution PT4+ Operator'S Manual Download Page 12](http://html1.mh-extra.com/html/pike/evolution-pt4/evolution-pt4_operators-manual_1555979012.webp)
10
...Setting the master (cont.) - Pedestrian
4
Where one or more pedestrian crossings
are required, on the master controller press
CROSSINGS/DEMAND
until the indicator for
the appropriate number of crossings is lit
(1-4). When 4 is lit, a further press of
CROSSINGS/DEMAND
will switch off
pedestrian mode.
3 seconds
safety period
7 seconds
standard crossing
period
Pedestrian
blackout
period
Pedestrian
clearance
period
(fixed)
(fixed)
(variable)
(variable)
5
Use the timing buttons within the
PEDESTRIAN CROSSING
section to set the appropriate
BLACKOUT
and
CLEARANCE
times as follows:
Choose a
BLACKOUT
period (in seconds) that is
sufficient to allow an able
bodied pedestrian to walk
the whole of the crossing.
The
CLEARANCE
setting
allows you to determine
an additional safety factor
(4 seconds is the usual
setting).
Next
• If you need to alter vehicle settings, go to
.
• To start operation, see right
Note: The timings that you choose in this section will apply
to all pedestrian crossings associated with this controller.
Note: To create a dedicated pedestrian crossing (i.e. a
single vehicle phase serving the pedestrian crossing only),
please use the ‘Pedestrian only’ setup shown on
.
The green crossing time is fixed at seven seconds
for almost all installations. However, there are
special circumstances where this time may need
to be adjusted. The pedestrian
MAX GREEN
control
allows this to be done on Evo control panels that
have been suitably adjusted. This feature is not
available on standard Evo controllers.