4 The REbus

TM

 Microgrid 

The  REbus

TM

  Microgrid  is  the  underlying  technology  that  allows  for  the  efficient  and  robust 

interconnection of different types of renewable energy products.  This section is informational only and 
not required knowledge for operation of your Pika B801 Charge controller. 

4.1 Simple and Efficient Power Distribution and Management 

The  REbus

TM

  Microgrid  architecture  was  designed  with  renewable  energy  in  mind.    A  clean-sheet 

approach to power distribution resulted in the most practical and efficient interconnection technology 
available.  The REbus

TM

 Microgrid operates at variable voltage in a defined band, b/- 180-200 V 

relative to ground which simultaneously allows for efficient power transmission, reduced shock hazard, 
and  simplified  electronics  for  a  bidirectional  converter  such  as  the  B801.    The  variable  voltage 
communicates energy  availability  to  the  attached  REbus

  devices,  which  allows  for  prioritized energy 

storage  and  load  shedding.    The  REbus

TM

  Microgrid  is  designed  to  support  many  different  types  of 

renewable  energy  sources  and  power  converters,  as  well  as  accommodating  future  380VDC  REbus

TM

 

Microgrid loads that are presently in development.  

4.2 Integrated Power Line Carrier (PLC) Communications 

The REbus

 Microgrid standard also specifies an optional power line carrier communication technology 

that enables devices on the same 

REbus™  M

icrogrid to communicate with one another.  The B801 uses 

this capability to gather information about your system such as the status and energy production of your 
Pika T701 Wind Turbine or your solar array, which connects to the REbus

 Microgrid through the Pika 

S2001 PV Link.   

4.3 REbus

 Control Protocol (RCP) 

REbus

 Control Protocol (RCP) is a communications protocol developed specifically for the transfer of 

data between REbus

-compatible power converters and data management products.  RCP is an open-

standard protocol which enables independent developers to interface with REbus

 products and create 

software  and  applications  to  enhance  user  experience.    Please  visit  the  Pika  Energy  website  to  learn 
more about RCP and the software applications that are currently available. 

 

 

Summary of Contents for B801 REcharge

Page 1: ...Pika B801 REcharge Off grid Charge Controller Operation Manual...

Page 2: ......

Page 3: ...Operation Manual B801 Bidirectional REbus Battery Charge Controller Revision Table Revision Date Changes 1 0 03 19 2015 Initial Release...

Page 4: ...on gateway enabling monitoring and control of your entire renewable energy system Unlike conventional charge controllers which only connect to one type of energy source Pika s B801 is designed to oper...

Page 5: ...vice 6 4 The REbusTM Microgrid 7 4 1 Simple and Efficient Power Distribution and Management 7 4 2 Integrated Power Line Carrier PLC Communications 7 4 3 REbus Control Protocol RCP 7 5 Designing a REbu...

Page 6: ...peration 19 7 7 Configurations 19 8 Internet Compatibility 22 8 1 Wi Fi Antenna 22 8 2 Configuring your Wi Fi Connection 23 8 2 1 Scan based network setup 23 8 2 2 Add network setup 24 8 3 Wi Fi Statu...

Page 7: ...efully read and follow all instructions cautions and warnings in this user manual Store this manual so that it is always easily accessible 1 1 Symbols used in this document WARNING This indicates a fa...

Page 8: ...o the charge controller installation manual for detailed information about the product and its intended use The charge controller may only be operated with REbus devices Do not use the charge controll...

Page 9: ...l necessary permits and agreements from your local government and your utility company for a legal and code compliant installation of your REbus Smart Microgrid system See the User Manual for more det...

Page 10: ...e REbusTM Microgrid is designed to support many different types of renewable energy sources and power converters as well as accommodating future 380VDC REbusTM Microgrid loads that are presently in de...

Page 11: ...terface 6 1 Overview of User Interface The B801 Charge Controller user interface is accessible via the LCD on the front cover It is designed to provide basic information such as power energy and batte...

Page 12: ...his blue LED is illuminated when a connection to a Wi Fi router has been established and is operating normally The blue LED is OFF if no Wi Fi connection has been established 6 3 LCD Display The LCD d...

Page 13: ...grid The color of the LED does not depend on the page that is currently displayed E User Input buttons These five buttons allow the user to scroll through display pages and command connected devices a...

Page 14: ...s Discharging Battery The B801 is exporting power to the REbusTM DC Microgrid Equalize Charging Battery The B801 is performing an equalize cycle on the batteries as initiated by the user ERR General A...

Page 15: ...harge Controller page Always configure the B801 before Enabling it Press the center button to access the various options for the charge controller From here use the arrows keys to navigate The B801 ma...

Page 16: ...If making changes to battery chemistry or number of cells commit changes and re enter the settings menu from the B801 device page before configuring the rest of the setpoints as described below To sa...

Page 17: ...criptions of the connection status messages and troubleshooting information C Wi Fi activity LED This blue LED will flash when the B801 is communicating on a Wi Fi network D Wi Fi settings not configu...

Page 18: ...Status Indicator LED This LED describes the state of all of the REbusTM devices connected to the REbusTM The LED will be RED if one or more REbusTM devices are reporting an error YELLOW if no REbusTM...

Page 19: ...are providing power to the REbus DC microgrid Always check for voltage on each terminal before performing any electrical service 7 3 Enable Disable Enable To permit the B801 to import and export powe...

Page 20: ...unt of current into the batteries After an allotted time has elapsed the current will have decreased significantly and charging will then enter Float charging stage at this point the batteries are nea...

Page 21: ...s are depleted to the point where they may be damaged rendering them unusable if they are discharged any further Please check with the battery manufacturer about extremely low voltage conditions for y...

Page 22: ...designed with a number of user configurable options allowing customization for various battery chemistries and voltages Recommended default setting are preprogramed into the B801 Setpoints should only...

Page 23: ...mistry Select 0 for custom batteries 1 for flooded lead acid 2 for Gel cell batteries and 3 for AGM lead acid batteries After changing this setpoint a default set of values for the chosen battery chem...

Page 24: ...he B801 will still source power to loads Below this voltage the B801 will enter a hibernation state see Low Battery Time Off and Low Battery Time On setpoint descriptions for more details 13 Absolute...

Page 25: ...the LCD screen Note that in order to receive firmware upgrades and to use the Pika REview online monitoring system See section 8 4 Pika account and the REview online monitoring system you must be con...

Page 26: ...nually For most networks using DHCP simply scan enter the network password and connect If manual configuration is desired selected the Advanced option select Manual and enter an IP address Subnet Mask...

Page 27: ...and DOWN to select and CENTER to perform the highlighted item Manual Step 4 Enter your network type If your network is secured with a password consult your wireless network router to determine whethe...

Page 28: ...ection If this fails to happen the status Offline will be displayed on the B801 on your REview page If your network name and password haven t changed simply power cycle the B801 using the switch on th...

Page 29: ...sources of 2 4 GHz radio If this happens repeatedly try moving your Wi Fi router closer to the B801 Connection failed Security mismatch This message will be displayed if the B801 has been configured...

Page 30: ...ration on the B801 Conn permanently lost Disassociate received This message indicates that your Wi Fi router has told the B801 to repeatedly reconnect This indicates an unusual authorization issue bet...

Page 31: ...oubleshooting the issue 10 Troubleshooting Guide Refer to the table below for guidance on how to troubleshoot your B801 If you are experiencing a symptom not addressed in this guide or require further...

Page 32: ...hnical support for further troubleshooting Charge controller shows devices that are no longer connected to REbusTM 1 Delete unwanted or disconnected devices by selecting Remove under the device page D...

Page 33: ...dware visit http profiles pika energy com Collect all device ID cards which will be needed for registration Consult the REview quickstart guide for more information regarding registration If you have...

Page 34: ...ontinuous DC discharging battery current 80 A Maximum continuous DC charging power at 50C 4000 W Maximum continuous DC discharging power at 50C 2800 W Ambient temperature 20 60 C Full power operation...

Page 35: ...32...

Reviews: