PD200 V6 Manual
12
Rev 1.2, Released, 05-02-2018
12
Rear Panel
Control
Type
Function
Ground
Ground/Earth
Temp
Output
Internal heatsink temperature, 0.1 V/degree (Celsius)
Overload
Output
+5V output when the amplifier is disabled or in overload state
Disable
Input
A voltage from +3V to +24V disables the amplifier
The rear panel connector and recommended mating plug is listed below.
Connector
Mating Connector
Manufacturer
PCB Component
4-Way Screw Terminal
TJ0631530000G
Amphenol
OQ0432510000G