© 2017 Pierce Manufacturing Inc. All Rights Reserved.
Husky 12 Foam System
/ 2-9
GENERAL
2-2.2f
Pick-Up Hose
Figure
2-10:
Pick-up
Hose
1012
A 1 in. flexible hose, with an end for insertion into foam containers, is provided. The hose has a 1 in. female swivel
NST thread swivel connector. (The hose is part of loose equipment.)
2-2.2g
Foam Check Valve
Figure
2-11:
Foam Check Valve
1013
The Foam Check Valve located in the foam supply line prevents water from flowing backwards through the foam
system and contaminating the foam supply.
2-2.3
Water Supply System
The water supply system supplies water to the foam injection manifold for foam to be added and distributed to the
foam/water discharges. This system consists of an in-line water check valve, water flowmeter and flowmeter
installation tee. The size of the check valve and the flowmeter installation tee are dependent on the number of foam/
water discharges in the system.