GENERAL SAFETY RULES AND OBLIGATIONS 

The following safety rules and obligations apply in general for using the PIEPS iPROBE BT: 

 

The PIEPS iPROBE BT must only be used in perfect condition. 

 

It is forbidden to change the PIEPS iPROBE BT without the written permission of Pieps GmbH. 

 

Do not attempt to repair damage or malfunctions without authorization. Instead, contact our support, 
who will tell how to proceed. The PIEPS iPROBE BT must not be used until the damage/malfunction has 
been repaired. 

 

The safety and operating instructions in the operating manual must be followed at all times. 

 

 

RESIDUAL RISKS | WARNINGS 

Even though the PIEPS iPROBE BT has been designed with maximum care and all safety-related facts have been 
taken into consideration, residual risks may exist and must be evaluated by means of a risk assessment. All 
residual risks and warnings from the risk assessment are listed in this chapter. 
 

 

DANGER

 

Risk of electric shock when touching the unit with electrical conductors. 

Keep yourself and the unit at a safe distance from energized conductors.

 

 

WARNING

 

Risk of puncture injures from the metal tip of the probe. 

Be aware of puncture injuries in the area of the tip. Never point the tip towards people, with 
the exception of the buried person.

 

 

WARNING

 

Risk of hearing damage due to the high noise level. 

Never hold the device directly next to your ear! A minimum distance of 50 cm is recommended

.

 

 

CAUTION

 

Risk of accidental folding up of the probe. 

Transport the unit in a folded and secured condition only (by means of a closure buckle or in 
the backpack emergency pocket). Ensure that the unit is stored properly in the backpack and is 
secured against being lost.

 

 

CAUTION

 

Risk of crushing from assembling and locking the probe tubes 

During tension, be aware of any possible risk of crushing when locking the individual probe 
tubes. Always hold the probe by the handle and push it into soft ground (snow). Lock the probe 
with the quick-closing latch.

 

 

CAUTION

 

Risk of crushing when fixing the quick-closing system 

Beware of crushing risks when fixing the quick-closing system.

 

 

WARNING

 

Risk of falling and slipping during operation with snow gloves 

When using the probe while wearing snow gloves, there is a risk of slipping on the probe tube, 
which can result in a loss of balance. The probe tube must not be used as a walking aid.

 

 

DANGER

 

Risk of battery explosion due to improper battery types or damaged batteries. 
Risk of incorrect battery capacity reading due to improper battery types. 

Use only batteries of type 

“Alkaline 

AA, LR6, 1,5V

“!

 

 

CAUTION

 

Risk of device malfunction or damage due to extreme temperatures 

Do not expose the device to extreme temperatures outside of the operating limits! Store the 
device protected from direct sunlight! Extreme temperatures can result in malfunction or 
damage.

 

NOTICE

 

If the PIEPS iPROBE BT is defect (system error self-test), no electronic functionalities are 
available, and any electronic support will lapse. In this case, use the PIEPS iPROBE BT like a 
classic avalanche probe.

 

NOTICE

 

The user must read the operating manual!

 

Summary of Contents for iPROBE BT 220

Page 1: ...ENGLISH 08 20...

Page 2: ...4 General description 8 4 1 Structure 8 4 2 Switching on Self Check 9 4 2 1 Self check 9 4 3 Functionality during operation 10 4 3 1 Check A Search mode Proximity indicator Hit indicator 10 4 3 2 Chec...

Page 3: ...T you have a product that is state of the art in terms of safety and user friendliness Despite this the PIEPS iPROBE BT can pose risks if used inappropriately or incorrectly We refer to possible hazar...

Page 4: ...their respective owners SN 12 digit serial number identifying the device and is used for device registration Recycling symbol Battery symbol indicating battery type and correct position Instruction p...

Page 5: ...e of action in an emergency as explained in specialist publications and material from avalanche courses must be followed The PIEPS iPROBE BT must always be folded away on descents and stowed securely...

Page 6: ...onical 270 cm 310 cm 350 cm 2 SAFETY This operating manual is structured in accordance with the applicable EU regulations and contains safety instructions Each individual is personally responsible for...

Page 7: ...Risk of accidental folding up of the probe Transport the unit in a folded and secured condition only by means of a closure buckle or in the backpack emergency pocket Ensure that the unit is stored pr...

Page 8: ...es 4 GENERAL DESCRIPTION STRUCTURE 1A Probe handle with LED display and loudspeaker for optical and acoustic indication of system status 1B Quick closing latch for reliable locking of the probe 1C Ela...

Page 9: ...he PIEPS iPROBE BT is switched on Warning tone for 3 seconds 5x piiiep see Troubleshooting If the PIEPS iPROBE BT is OK self check OK a green LED light lits for 1 second The LED light of the Check A1...

Page 10: ...ransmitting beacon the proximity indicator Check A2 is indicated From a distance of approx 0 5 0 m the PIEPS iPROBE BT signals a hit Check A3 NOTICE The proximity and hit indicators operate for each t...

Page 11: ...ti ti ti_etc After deactivation of the transmitting beacon the display of the receiving beacon shows the next strongest signal The rescuer immediately follows the new signal while other rescuers star...

Page 12: ...lding process with the bottom probe tube and fold the next probe tube parallel to the first one 2B Push the tube until it stops 2C Repeat the process with the remaining probe tubes until the PIEPS iPR...

Page 13: ...ny other risks How many victims Determine the primary search area 2 Make a brief emergency call EU 112 AT 140 CH 1414 IT 118 FR 15 NA 911 3 Burial search Signal search eyes ears beacon Coarse search s...

Page 14: ...within 50cm to the burial IMPORTANT Leave probe in place during the whole digging work The probe serves as an indispensable orientational guide 4 5 2 Combination of fine search and pinpointing This is...

Page 15: ...n 5 minutes the PIEPS iPROBE BT needs to be deactivated and activated again 4 A successful connection is indicated with a permanent blue and a flashing green LED light 5 After a successful connection...

Page 16: ...or contact our support support pieps com BATTERY REPLACEMENT The PIEPS iPROBE BT analyses the charge remaining in the battery each time the probe is switched on If the charge reaches a critical level...

Page 17: ...N Risk of device malfunction or damage due to extreme temperatures Do not expose the device to extreme temperatures outside the operating limits Store the device protected from direct sunlight Extreme...

Reviews: