PIE 820-ELITE Operating Instructions Manual Download Page 1

PIE 820-ELITE

Multifunction

Process Calibrator

mA • V • pH • TC • 

Ω

 • RTD • Freq • Pressure

Operating Instructions

PIE 820-ELITE

Multifunction

Process Calibrator

mA • V • pH • TC • 

Ω

 • RTD • Freq • Pressure

Operating Instructions

Practical Instrument Electronics

82 East Main Street Suite 3.14 • Webster, NY 14580 USA

Tel: 585.872.9350 • Fax: 585.872.2638 • [email protected] • www.piecal.com

www.

GlobalTestSupply

.com

Quality PIECAL Products Online at:

[email protected]

Summary of Contents for 820-ELITE

Page 1: ...ifunction Process Calibrator mA V pH TC RTD Freq Pressure Operating Instructions Practical Instrument Electronics 82 East Main Street Suite 3 14 Webster NY 14580 USA Tel 585 872 9350 Fax 585 872 2638...

Page 2: ...easure Transmitters with Leak Detection 16 Voltage Millivolt Source V mV 18 Read V mV 19 pH Source pH 20 Thermocouple Source T C 22 Read T C Sensors 23 Resistance Source Resistance 24 Read Resistance...

Page 3: ...99 Hz 0 0 to 9999 9 Hz and 0 000 to 20 000 kHz Checkout resistance instruments loop wiring problems Source and read resistance from 0 00 to 410 00 and 0 0 to 4001 0 ohms Beep out connections with the...

Page 4: ...gs for instant recall with the EZ CHECK switch Choose between 2 3 5 11 steps or RAMP to increase and decrease the output between Zero and Span from 5 6 7 8 9 10 15 20 25 30 and 60 seconds Measure temp...

Page 5: ...ck Leads with Banana Plugs Spade Lugs OPTIONAL Ni MH 1 Hour Charger with 4 Ni MH AA Part No 020 0103 Batteries 100 120 V AC input for North America Only T C Wire Kit 1 for Types J K T E Part No 020 02...

Page 6: ...ill automatically turn off To change the batteries remove the rubber boot remove the battery door from the back of the unit by sliding the door downward This allows access to the battery compartment R...

Page 7: ...t value is on the display Press and hold the EZ Dial knob until STORED appears to store the value Release the EZ Dial knob 3 Instantly output your SPAN and ZERO output settings by moving the EZ CHECK...

Page 8: ...with the power off These values can easily be changed to suit the calibration requirements The values stored in the HI and LO positions are also used for Auto Stepping READ Slide the switch to the SET...

Page 9: ...ut value changes SELECTING FUNCTIONS The EZ DIAL knob is used to setup the PIE 820 ELITE to match the instrument to be calibrated or signal to be measured Each time you turn on the PIE 820 ELITE the L...

Page 10: ...s the Double Click Menus to select each function and the options for each function Available choices are shown in grey EXIT FUNCTION V RANGE 10V 1V 60V 100mV Source mA Simulate 2 Wire Transmitters Rea...

Page 11: ...0 a 4274 Cu 50 a 4280 Ni 120 a 6720 Ni 110 a 5801 Source Read Thermocouples Source RTD Operating Instructions Double Click Menus Read RTD EXIT FUNCTION OHMS RANGE 400 4000 WIRE MODE 234W EXIT FUNCTION...

Page 12: ...ings are remembered even with the power off EXIT MENU exits this menu immediately and saves any changes Menu will automatically exit after 15 seconds of inactivity AUTO OFF If AUTO OFF is ON the unit...

Page 13: ...using the calibrator in areas with enough ambient light to read the display STEPS pressing the knob will cycle through 2 3 5 11 and RAMP The endpoints of the steps or ramp are based on the values stor...

Page 14: ...settings and press the knob to make your selection Select mA for the FUNCTION and SOURCE for the MODE Choose either mA or and whether you need the 250 HART resistor active in the loop Connect the outp...

Page 15: ...croll through the settings and press the knob to make your selection Select mA for the FUNCTION and 2W SIM for the MODE Choose either mA or and whether you need the 250 HART resistor active in the loo...

Page 16: ...either mA or and whether you need the 250 HART resistor active in the loop Connect the red input lead of the PIE 820 ELITE to the more positive point of the break and the black input to the more negat...

Page 17: ...he settings and press the knob to make your selection Select mA for the FUNCTION and PWR MEAS for the MODE Choose either mA or and whether you need the 250 HART resistor active in the loop Disconnect...

Page 18: ...the 820 ELITE to the plus input of the device and the black source lead from the mA to the minus The PIE 820 ELITE supplies a nominal 24 volts DC at 24 mA to the 2 Wire Transmitter or loop The curren...

Page 19: ...er and is leaking somewhere in the loop LEAK ERROR OVER RANGE PWR MEAS LEAK ERROR 00 28 12 280mA PWR MEAS Typical Error Conditions READ SOURCE HI SET LO OFF MAX READ MIN READ OVERLOAD Hz SYNC Double C...

Page 20: ...Turn the knob to scroll through the settings and press the knob to make your selection Select V for the FUNCTION and 10V or 80 mV for the RANGE Connect the output leads of the PIE 820 ELITE to the in...

Page 21: ...ress the knob to make your selection Select V for the FUNCTION and 10V 1V 60V or 100 mV for the RANGE Connect the red input lead of the PIE 820 ELITE to the more positive point of the break and the bl...

Page 22: ...black lead from the mV jack to the minus input You may also use the optional adaptor jack 020 0 if you require BNC connections Instantly output your SPAN and ZERO output settings by moving the EZ CHEC...

Page 23: ...rating correctly The 820 ELITE simulates 0 000 to 14 000 pH 25 C corresponding to 414 12 to 414 12 mV Once the pH instrument has been adjusted against the PIE 820 ELITE reconnect the pH probe and chec...

Page 24: ...the proper type of thermocouple wire via the miniature thermocouple socket Instantly output your SPAN and ZERO output settings by moving the EZ CHECK switch between HI and LO You may also select any...

Page 25: ...e socket If no sensor is connected a wire is broken or the sensor is burned out OPEN TC will appear on the display Signals above the maximum scale are limited by protection circuitry with OVERRANGE on...

Page 26: ...wires Instantly output your SPAN and ZERO output settings by moving the EZ CHECK switch between HI and LO You may also select any third output setting such as mid range using the SET position on the...

Page 27: ...4 wires If continuity is selected resistance is measured up to 400 0 The beeper will sound and appears on the display when resistances below 100 0 are measured Signals above the maximum scale are lim...

Page 28: ...onnect the PIE 820 ELITE to the inputs of the device using 2 3 or 4 wires Instantly output your SPAN and ZERO output settings by moving the EZ CHECK switch between HI and LO You may also select any th...

Page 29: ...all wires from the sensor and connect the PIE 820 ELITE to the inputs of the device using 2 3 or 4 wires Signals above the maximum scale are limited by protection circuitry with OVERRANGE flashed on...

Page 30: ...pickups The output signal is a zero crossing square wave with a fixed amplitude of 6 V peak to peak from 1 and 5 V Instantly output your SPAN and ZERO output settings by moving the EZ CHECK switch be...

Page 31: ...aximum scale are limited by protection circuitry with OVERRANGE flashed on the display and the red OVERLOAD LED lit The PIE 820 ELITE measures the input signal and constantly updates the display with...

Page 32: ...pressure instrument to be checked The following screen will appear each time pressure is selected to remind you that the switch on the Multical Pressure Module MUST be set to PSI for the PIE 820 ELIT...

Page 33: ...the highest reading and to MIN to see the lowest reading Press and hold the knob e for 2 seconds to clear the MAX and MIN readings 30 psi 2 bar Gauge Absolute Modules Units Maximum PSI 30 000 Inches...

Page 34: ...ight 12 1 ounces 0 34 kg with boot batteries Batteries Four AA Alkaline 1 5V LR6 Battery life Read Functions 20 hours Source mA 14 hours 12 mA into 250 Pwr Meas mA 12 hours at 20 mA SourceV T C RTD Hz...

Page 35: ...20 00mA Loop drive capability 1200 at 20 mA for 15 hours nominal 950 with Hart Resistor enabled mA 2 Wire Transmitter Simulation Accuracy Same as Source Power Measure Voltage burden 2V at 20 mA Overlo...

Page 36: ...Compensation 0 1 C 0 01 C Output Impedance 1 Ohm Source Current 20 mA drives 80 mV into 10 Ohms Thermocouple Read Accuracy Cold Junction Compensation Same as Thermocouple Source Input Impedance 1 Mego...

Page 37: ...mA of External Excitation Current 2 Wire Accuracy 0 03 of Full Scale 0 075 Ohms 0 03 of Full Scale 0 075 Ohms Add 0 1 Ohm to specifications listed above Resistance Ranges 0 0 to 410 00 to 4001 0 Ohms...

Page 38: ...tude 10 microseconds Output Impedance 1 Ohm Source Current 1 mA rms at 20 kHz Short Circuit Duration Infinite Optical Coupling Green LED HZ SYNC flashes at output frequency Frequency Read Ranges Accur...

Page 39: ...2 0 to 2500 0 1 1 T 260 0 to 230 0 2 9 436 0 to 382 0 5 2 230 0 to 210 0 1 0 382 0 to 346 0 1 9 210 0 to 50 0 0 8 346 0 to 58 0 1 4 58 0 to 50 0 0 3 58 0 to 122 0 0 6 50 0 to 400 0 0 2 122 0 to 752 0...

Page 40: ...1 2 50 0 to 950 0 0 4 58 0 to 1742 0 0 8 950 0 to 1300 0 0 5 1742 0 to 2372 0 1 0 G W 100 0 to 350 0 1 7 212 0 to 662 0 3 0 350 0 to 1700 0 0 8 662 0 to 3092 0 1 5 1700 0 to 2000 0 1 0 3092 0 to 3632...

Page 41: ...1395 0 0 7 2192 0 to 2543 0 1 2 L J DIN 200 0 to 50 0 0 4 328 0 to 58 0 0 7 50 0 to 300 0 0 2 58 0 to 572 0 0 4 300 0 to 900 0 0 3 572 0 to 1652 0 0 5 U T DIN 200 0 to 50 0 0 6 328 0 to 58 0 1 1 50 0...

Page 42: ...0 2 0 3 0 4 0 5 328 0 to 68 0 68 0 to 680 0 680 0 to 1202 0 1202 0 to 1562 0 0 4 0 6 0 8 0 9 Pt 100 Ohm US Lab 1 3926 200 0 to 20 0 20 0 to 360 0 360 0 to 660 0 660 0 to 850 0 0 2 0 3 0 4 0 5 328 0 to...

Page 43: ...ir Replacement Warranty RP WAR B our equipment is warranted against ANY damage or malfunction that may cause the unit to fail for a period of three 3 years from the date of shipment This warranty is l...

Page 44: ...et Suite 3 14 Webster NY 14580 USA Tel 585 872 9350 Fax 585 872 2638 sales piecal com www piecal com Copyright 2014 All rights reserved 820 E 9002 Rev B 27 May 2014 www GlobalTestSupply com Quality PI...