Picomed PicoCombi Documentation Download Page 1

 

 

Brokelandsheia, N-4993 Sundebru, 

Ph

 +47 3711 9950 

Fax

 +47 3711 9951 

E-mail

[email protected] 

Foretaksnr

 962 211 631 MVA

 

Environmental control 

 

Documentation for 

PicoCombi Loudspeaking analog 

telephone and doorphone 

 

 

 

Summary of Contents for PicoCombi

Page 1: ...landsheia N 4993 Sundebru Ph 47 3711 9950 Fax 47 3711 9951 E mail firmapost picomed no Foretaksnr 962 211 631 MVA Environmental control Documentation for PicoCombi Loudspeaking analog telephone and doorphone ...

Page 2: ...ate Kap 8 12 07 05 Bent Håvard Sollid Removed electrical diagram for doorphone since this is a part of the documentation for the doorphone Changed colours with reference to wiring for the EFP 2005 Ch 7 2 2 23 05 06 Bent Håvard Sollid Updated in accordance to SW version 1 05 disable ring sound Ch 1 3 1 1 3 4 3 5 8 4 3 6 Changed revision list to updated look Contents Documentation PicoCombi 1 Introd...

Page 3: ...tings 20 5 Maintenance 20 6 Trouble shooting 20 6 1 When errors arise 21 7 Technical information 21 7 1 Fixed mounting 21 7 2 Electrical connections 21 7 2 1 Fixed 12 VDC and external IR sensor 22 7 2 2 Doorphone 23 7 2 3 Multiple indoor units 24 7 2 4 Door indicator 24 7 2 5 External switches 25 7 2 6 External loudspeaker 25 7 2 7 External microphone 25 7 3 Jumpers 25 7 4 Default recycling 25 7 5...

Page 4: ...he one you are speaking with in the telephone or in the outdoor phone Switches can be connected to the loudspeaking products to control the main functions in addition to external speaker and microphone A built in automatic answering function can be activated if required There is a number of programmable settings to make I e the number of ringing signals before the automatic answering function trig...

Page 5: ...ff and to refuse anyone at the outdoor Hand with telephone symbol Enable disable automatic answering function Door symbol Get in touch with anyone at the outdoor unit and to unlock open the door with 2 2 Light indicators There are 4 light indicators on the front of PicoCombi Denomination Function Power on Green Illuminates when power are connected to the device Telephone receiver Red Illuminates w...

Page 6: ...ou may hook off by the use of the remote controller key on device external switch or by the help of the automatic answering function if this is enabled When the automatic answering function activates there will be given a warning tune and then the PicoCombi hooks off after a predefined number of ringing signals the number can be changed in advanced programming mode 3 1 1 Disable ringing sound If t...

Page 7: ... the D button on the remote controller Press the door key on the front of PicoCombi Press key connected to external connection Door Or until the connection is disabled without opening the door by Press the E button on the remote controller Press the telephone key on the PicoCombi Press key connected to external connection Ph PicoCombi automatically disconnects after 45 seconds It is possible to co...

Page 8: ...omatic answering function Automatic answering indicator changes status 3 5 2 Hook off 0 9 Transmit DTMF 0 9 External switches 1 3 Transmit phone book number no 1 3 A Transmit DTMF B Transmit DTMF C Generate R key signal hook flash D Door key on device Park a telephone conversation and establish communication to primary or secondary doorphone E Telephone key on device End conversation F Volume adju...

Page 9: ...nts for the telephone function on PicoCombi may be adjusted with the remote controller in 5 steps If the volume has been changed the new value is stored and used for later telephone conversations When pressing F on remote controller the volume will increase and it will be indicated by one short beep for each press When changing from volume 4 to 5 maximum it will be indicated by a long beep The nex...

Page 10: ...let message number 1 be copied to situation 1 and situation 4 also done in advanced programming mode When John answer the doorphone situation number 1 in the list above or if he is answering the telephone situation number 4 in the list above message number 1 will be automatically played back in the beginning of the conversation 3 5 8 Automatic answering function The automatic answering function ca...

Page 11: ... for both It is only possible to get in touch with one outdoor unit at the same time When a bell button is pressed a chime will sound ding dong A two way voice controlled communication will be established with the use of remote controller door switch on device external switch connected to Door at the reverse of the device or automatically if automatic answering function is enabled If the automatic...

Page 12: ...doorphone Page 12 3 5 13 Accessories The following accessories are available External switches to control telephone line doorphone and phone book numbers 1 3 Outdoor units for doorphone External IR sensors External loudspeaker External microphone ...

Page 13: ...cates maximum volume Automatic answering mode Press key F in standby mode or Press automatical answering mode key on PicoCombi A yellow light indicator indiactes enabled function PicoCombi hooks off automatically after 5 ringing signals PicoCombi enables doorphone automatically after 5 seconds PicoCombi hooks on after 30 seconds telephone conversation PicoCombi disables doorphone after 45 seconds ...

Page 14: ......

Page 15: ...ing mode to leave the mode Invalid keystrokes will be indicated with the auditive feedback error and the sequence are ready to start from the beginning This is one situation where it is important to have done the auditive feedback recordings in point 31 in advanced programming mode 4 1 Getting started When installing a PicoCombi you should as a first job enter advanced programming mode and record ...

Page 16: ...ght in the product It is important that the technician choose the best settings so the user can make the most out of the benefits of the product Especially with the built in speech functions which are available When installing a PicoCombi you should as a first job enter advanced programming mode and record speech to the auditive feedback point 31 in the list This should be done because this feedba...

Page 17: ...ill be shorter if dialling tone is detected 09 Stored digit 100 999 115 Pressed digit D Saved Number of milliseconds for R key flash 10 Empty 0 Pressed digit D Saved Delete and deactivate learned IR 11 Stored digit 00 11b 10 Pressed digit D Saved Activate IR format 0 off 1 on 1 Digit 1 indicate New Assistant 2 Digit 2 indicate Gewa 12 Stored digit 0 31 5 Pressed digit D Saved User code for New Ass...

Page 18: ...orded message will be played back The speech will be stored while recording it not when pressing the D key Recording should be done in a silent environment with a clear voice with the mouth near the microphone which is situated in the left front corner of the device 26 30 To activate a message you may enter one two or three digits value 1 2 or 3 for each situation in the prefered order The value i...

Page 19: ...sensors The following 3 things can be done a Train the device with an IR remote controller Point the remote controller against the IR receiver placed under the dark glass in the front of the device The distance from the front of the remote controller and the IR glass on the device should be approximately 2 5 cm Press the key designated to the channel number which are active1 After the first succes...

Page 20: ...or 5 seconds A long Beep will sound when the process are finished Maximum time for the points 1 5 is 8 seconds Maximum time between the points 5 6 is 8 seconds When restoring the values the following are done Alle telephone numbers in the telephone book will be deleted Redial memory will be deleted Volume level will be set to value 3 for both telephone and doorphone system Automatic answering func...

Page 21: ...plier National distributor 7 Technical information The device is made by Injection moulded box in recycleable ABS Frontglass made of plexiglass Polycarbonat 2 PCBs a maincard in bottompart with contacs and a keypad PCB mounted in top part Microphone and loudspeaker mounted in rubber gaskets to dampen mechanical vibrations Frontfoil Productname light indicators and keys are visually viewed on it 7 ...

Page 22: ...ontrols LED on external IR sensor s IR IR signal from external IR sensor s 1 or 2 external IR sensors Picomed ES2 can be connected to the terminal strip They will be supplied with 0 and 12 VDC together with LED signal from the device The IR signal wires are also connected at the same terminal strip There is a light indicator placed in the front of the main PCB which indicates that IR is received T...

Page 23: ... 2 2 Doorphone A doorphone outdoor unit named Picomed EFP can be connected as the table shows on the terminal strips DP1 and DP2 on PicoCombi DP1 and DP2 are with exception of connection D SW at DP1 equal They have the following connections with recommended colours ...

Page 24: ...With jumpers on the main board it is possible to choose between refer to chapter 7 3 for details about jumper settings Control doorlock with 12 VDC from the device maximume 1 A current draw Control doorlock with a N O potensial free relay maximum 1 A 32 VAC VDC Tip The microphone in the outdoor unit is polarized If the connection wires are exchanged there will be no sound from the outdoor unit int...

Page 25: ... changing place for jumpers on the main board The following can be done Denomination Short circuit Function S253 2 and 3 Relay to control door 1 has closed circuit N O 1 and 2 3 and 4 Relay to control door 1 supplies door 1 with 12 VDC to DOR and 0 VDC to DOR Maximum 1 A S254 2 and 3 Relay to control door 2 has closed circuit N O 1 and 2 3 and 4 Relay to control door 2 supplies door 2 with 12 VDC ...

Page 26: ... other IR remote controller with 16 channels Keypad for main functions External switches may be connected Power supply Enclosed Friwo 15 1433 Medical Ferrite Power consumption 250 mA internal consumption 1 0 A output to control doorlock opener Temperature Designed for indoor use 0 C to 40 C Measurements LxWxH 165 x 210 x 50 mm Weight 0 5 kg without powersupply and cable Key size 20 x 12 mm ovale M...

Page 27: ......

Page 28: ...8 Drilling template ...

Reviews: