Installation and
Operation Manual
MOR-CS
Mini Headend Cooling System
Operation
Manual
Rev. 07/06
Ph:800-421-6511
www.picomacom.com
MOR-CS manual.qxd 7/6/06 11:53 AM Page 1
Page 1: ...Installation and Operation Manual MOR CS Mini Headend Cooling System Operation Manual Rev 07 06 Ph 800 421 6511 www picomacom com MOR CS manual qxd 7 6 06 11 53 AM Page 1 ...
Page 2: ... kitchen sink laundry tub in a wet basement or near a swimming pool and the like 8 Accessories Do not place this product on an unstable cart stand tripod bracket or table The product may fall causing serious injury to a child or adult and serious damage to the appliance 9 Ventilation This video product should never be placed near or over a radiator or heat register This video product should not be...
Page 3: ...ain or water d If the product does not operate normally by following the oper ating instruction Adjust only those controls that are covered by the operating instructions An improper adjustment may result in damage and will often require extensive work by a qualified tech nician to restore the product to its normal operation e If the product has been dropped or the cabinet has been damaged f When t...
Page 4: ... Macom backs this product with its industry leading 5 year limited warranty Mini Headend Cooling System MOR CS Increases electronic equipment longevity reducing equipment temperature by 15 F Improves computer floor forced air systems enhancing the normal cooling process Large mesh covered flow channels provide increased air circulation Low noise brushless blowers produce extremely quiet smooth ope...
Page 5: ...W DC power requirements Rated fan voltage 12 Vdc Operating voltage 8 12 Vdc Fan mechanical specs Fan Speed 2500 rpm Max air flow 27 99 m3 n Max air pressure 12 13CmH20 Operating Temperature 0 to 50 C Dimensions 19 W x 7 5 D x 1 75 H Weight 6 15 lbs Specifications Ordering Information MOR CS Mini Headend Cooling System MOR CS manual qxd 7 6 06 11 53 AM Page 5 ...
Page 6: ... ON OFF Switch Switch activates and deactivates unit 3 Air Intake Vents Located on bottom of unit these vents draw the heated air away from the MPC 12 chassis 4 Convenience Outlet The AC output has a 600W capacity 5 Power Cord The three prong power plug connects to a 120Vac 60Hz electrical output MOR CS manual qxd 7 6 06 11 53 AM Page 6 ...
Page 7: ... Installation Procedure For optimum cooling performance the MOR CS is mounted directly above the MPC 12 mini mod chassis Secure the unit onto the headend rack with the 4 mounting screws and fiber washers provided MOR CS manual qxd 7 6 06 11 53 AM Page 7 ...
Page 8: ...product Be prepared to provide 1 The model number and channel number of the product 2 The date of purchase 3 A specific identification of the problem Deliver the products to Pico Macom Inc or ship the products in the original packing material at the address at the bottom of the page Include satisfactory evidence of the date of purchase Products will not be accepted by Pico Macom Inc without the RA...