background image

Artisan Technology Group 

is your source for quality 

new and certified-used/pre-owned equipment

• 

FAST SHIPPING AND 

DELIVERY

• 

TENS OF THOUSANDS OF 

IN-STOCK ITEMS

•  EQUIPMENT DEMOS
• 

HUNDREDS OF 

MANUFACTURERS 

SUPPORTED

•  LEASING/MONTHLY

 

RENTALS

•  ITAR CERTIFIED

           

SECURE ASSET 

SOLUTIONS

SERVICE CENTER REPAIRS

Experienced engineers and technicians on staff 

at our full-service, in-house repair center

WE BUY USED EQUIPMENT

Sell your excess, underutilized, and idle used equipment 

We also offer credit for buy-backs and trade-ins

www.artisantg.com/WeBuyEquipment

                        

REMOTE INSPECTION

Remotely inspect equipment before purchasing with 

our interactive website at

 

www.instraview.com

LOOKING FOR MORE INFORMATION? 

Visit us on the web at

 

www.artisantg.com

    

for more 

information on price quotations, drivers, technical 

specifications, manuals, and documentation

Contact us:

 

 

(888) 88-SOURCE  |  [email protected]  |  www.artisantg.com

SM

View

Instra

Summary of Contents for PXI 40-795-001

Page 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Page 2: ...D 40 795 796 pickering Issue 3 2 May 2017 User Manual 8 16 Tributary Daisy Chain Switch Balanced Model Nos 40 795 001 40 796 001 pickeringtest com pickering Artisan Technology Group Quality Instrument...

Page 3: ...D No part of this publication may be reproduced transmitted transcribed translated or stored in any form or by any means without the written permission of Pickering Interfaces Technical details contai...

Page 4: ...to fulfil all relevant environmental laws and regulations and reduce wastes and releases to the environment Pickering Interfaces aims to design and operate products in a way that protects the environ...

Page 5: ...ges WARNING CAUTION An appropriate safety instruction should be followed or caution to a potential hazard exists Refer to the relevant instructions detailed within the product manual HEAVY If this pro...

Page 6: ...3 1 Pre Operation Checks 3 1 Hardware Installation 3 2 Software Installation 3 2 Testing Operation 3 3 Section 4 Programming Guide 4 1 Programming Options For Pickering PXI Cards 4 1 Module Architect...

Page 7: ...Page VI 8 16 TRIBUTARY DAISY CHAIN SWITCH BALANCED 40 795 796 pickering THIS PAGE INTENTIONALLY BLANK Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 8: ...assemblies from equipment using these devices must be earthed by a wrist strap and a resistor at the point provided on the equipment 2 Soldering irons used during the repair operations must be low vol...

Page 9: ...Page VIII 8 16 TRIBUTARY DAISY CHAIN SWITCH BALANCED 40 795 796 pickering THIS PAGE INTENTIONALLY BLANK Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 10: ...y Chain Switch Balanced Module 40 796 001 Multiple modules can be cascaded together to form very large systems for example a 7 slot PXI chassis can contain a 112 tributary switching system and an 18 s...

Page 11: ...e Max Power 1x108 operations 2x105 operations Total Switching Time Relay Mechanical Setting Time 10ms 3ms R F Specification Characteristic Impedance 100 120 Insertion Loss Test Signal to Rx Tx Daisy C...

Page 12: ...ring Interfaces LXI Modular Chassis For information on driving your switching solution in an LXI environment refer to the LXI Product Guide PXI CompactPCI Compliance The module is compliant with the P...

Page 13: ...ently we reserve the right to vary from the description given in this data sheet PCB Layout for the 40 796 16 Tributary Daisy Chain Switch Module showing Mother and Daughter cards The 8 tributary vers...

Page 14: ...ard and daughterboard The motherboard and daughterboard are connected via ribbon cable The relays are energised via control signals from relay drivers U9 to U16 40 795 or relay drivers U9 to U24 40 79...

Page 15: ...6 10 111 U13 LINE DRIVER U14 LINE DRIVER U15 LINE DRIVER U16 LINE DRIVER U17 LINE DRIVER U18 LINE DRIVER U19 LINE DRIVER U20 LINE DRIVER U21 LINE DRIVER U22 LINE DRIVER U23 LINE DRIVER U24 LINE DRIVER...

Page 16: ...IT 1 Ch7 SUB UNIT 2 Ch6 SUB UNIT 2 Ch7 SUB UNIT 1 Ch8 SUB UNIT 2 Ch8 DEFAULT SWITCH CONDITION ILLUSTRATED RL45 RL44 RL43 RL46 RL40 RL39 RL38 RL37 RL34 RL33 RL32 RL31 RL28 RL27 RL26 RL25 RL22 RL21 RL20...

Page 17: ...NIT 2 Ch13 SUB UNIT 1 Ch14 SUB UNIT 1 Ch15 SUB UNIT 2 Ch14 SUB UNIT 2 Ch15 SUB UNIT 1 Ch16 SUB UNIT 2 Ch16 NOTE EACH SWITCH PATH REPRESENTS A TWO POLE CONNECTION DEFAULT SWITCH CONDITION ILLUSTRATED R...

Page 18: ...dule s will connect with Ensure the chassis is not connected to the electrical supply 3 Ensure that the designated area for the chassis containing the module is of flat and solid construction to withs...

Page 19: ...equate ventilation The module should be installed in accordance with the following procedure 1 Ensure that the system is turned OFF but still connected to mains so that it remains grounded 2 Choose an...

Page 20: ...r via the Start menu Start Menu Pickering Interfaces Ltd General Soft Front Panel A selector panel will appear listing all installed Pickering PCI PXI or LXI switch cards and resistor cards Click on t...

Page 21: ...8 16 TRIBUTARY DAISY CHAIN SWITCH BALANCED 40 795 796 pickering SECTION 3 INSTALLATION THIS PAGE INTENTIONALLY BLANK Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artis...

Page 22: ...s both pipx40 and Pilpxi documents are included in the Pipx40vpp software installation IVI Driver for Windows pi40iv The pi40iv IVI Interchangeable Virtual Instrument driver supports all Pickering Int...

Page 23: ...NET A NET native driver is also available Once again this may be used for both LXI and PXI card control SOAP Pickering LXI products include a SOAP interface which is usable from a wide variety of plat...

Page 24: ...Connection Normally closed Connection Normally Open Connection Common Connections Definitions A multiplexer MUX sub unit may only have 1 bit selected setting a bit will clear a previously set bit A m...

Page 25: ...ut disconnected Tx Tx MUX Rx MUX disconnected 1 1 0 In Out Rx Rx MUX Tx Tx MUX 1 1 1 Rx Tx In Out Rx MUX Tx MUX disconnected All Other Settings Rx Tx All others disconnected Sub units 3 and 4 are simp...

Page 26: ...UNIT 2 Tx Route Channel 1 Relay 3 RL104 Bit No Function Relay No 2 Channel 2 Relay 1 RL110 1 Channel 1 Relay 1 RL3 Channel 2 Relay 2 RL108 Channel 1 Relay 2 RL4 3 Channel 3 Relay 1 RL110 2 Channel 2...

Page 27: ...ay 1 RL39 Channel 7 Relay 2 RL38 Channel 7 Relay 2 RL40 8 Channel 8 Relay 1 RL43 8 Channel 8 Relay 1 RL45 Channel 8 Relay 2 RL44 Channel 8 Relay 2 RL46 9 Channel 9 Relay 1 RL49 9 Channel 9 Relay 1 RL5...

Page 28: ...107 Channel 5 Relay 3 RL117 Channel 5 Relay 3 RL102 6 Channel 6 Relay 1 RL126 6 Channel 6 Relay 1 RL111 Channel 6 Relay 2 RL122 Channel 6 Relay 2 RL107 7 Channel 7 Relay 1 RL126 7 Channel 7 Relay 1 RL...

Page 29: ...L30 6 Channel 6 Relay 1 RL35 Channel 6 Relay 2 RL36 7 Channel 7 Relay 1 RL41 Channel 7 Relay 2 RL42 8 Channel 8 Relay 1 RL47 Channel 8 Relay 2 RL48 9 Channel 9 Relay 1 RL53 Channel 9 Relay 2 RL54 10 C...

Page 30: ...a data 0 0x20 Sets 6th bit Selects RL31 and Rl32 All other relays are set to off pipx40_setChannelPattern vi sub_unit data PROGRAMMING THE MODULE 40 795 796 Here are some simple examples of using the...

Page 31: ...Ch7 SUB UNIT 2 Ch6 SUB UNIT 2 Ch7 SUB UNIT 1 Ch8 SUB UNIT 2 Ch8 DEFAULT SWITCH CONDITION ILLUSTRATED RL45 RL44 RL43 RL46 RL40 RL39 RL38 RL37 RL34 RL33 RL32 RL31 RL28 RL27 RL26 RL25 RL22 RL21 RL20 RL1...

Page 32: ...Ch13 SUB UNIT 1 Ch14 SUB UNIT 1 Ch15 SUB UNIT 2 Ch14 SUB UNIT 2 Ch15 SUB UNIT 1 Ch16 SUB UNIT 2 Ch16 NOTE EACH SWITCH PATH REPRESENTS A TWO POLE CONNECTION DEFAULT SWITCH CONDITION ILLUSTRATED RL93 R...

Page 33: ...RL40 RL39 RL38 RL37 RL34 RL33 RL32 RL31 RL28 RL27 RL26 RL25 RL22 RL21 RL20 RL19 RL16 RL15 RL14 RL13 RL10 RL9 RL8 RL7 RL4 RL3 RL2 RL1 RL48 RL47 RL42 RL41 RL36 RL35 RL30 RL29 RL24 RL23 RL18 RL17 RL12 R...

Page 34: ...UB UNIT 1 Ch4 SUB UNIT 2 Ch4 SUB UNIT 1 Ch5 SUB UNIT 2 Ch5 SUB UNIT 1 Ch6 SUB UNIT 1 Ch7 SUB UNIT 2 Ch6 SUB UNIT 2 Ch7 SUB UNIT 1 Ch8 SUB UNIT 2 Ch8 RL45 RL44 RL43 RL46 RL40 RL39 RL38 RL37 RL34 RL33 R...

Page 35: ...16 TRIBUTARY DAISY CHAIN SWITCH BALANCED 40 795 796 pickering SECTION 4 PROGRAMMING GUIDE THIS PAGE INTENTIONALLY BLANK Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www ar...

Page 36: ...D RX 3 1 RX 3 2 RX 4 1 RX 4 2 GND RX 5 1 RX 5 2 GND RX 6 1 RX 6 2 RX 7 1 RX 7 2 GND RX 8 1 RX 8 2 GND RX 9 1 RX 9 2 RX 10 1 RX 10 2 GND RX 11 1 RX 11 2 GND RX 12 1 RX 12 2 RX 13 1 RX 13 2 GND RX 14 1...

Page 37: ...TRIBUTARY DAISY CHAIN SWITCH BALANCED 40 795 796 pickering SECTION 5 CONNECTOR INFORMATION THIS PAGE INTENTIONALLY BLANK Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www...

Page 38: ...le through the Programs Pickering PXI Utilities menu generates a diagnostic report of the system s PCI configuration highlighting any potential configuration problems Specific details of all installed...

Page 39: ...ARY DAISY CHAIN SWITCH BALANCED 40 795 796 Page 6 2 pickering SECTION 6 TROUBLE SHOOTING THIS PAGE INTENTIONALLY BLANK Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www art...

Page 40: ...ing Interfaces Modular LXI Chassis such as the 60 102B and 60 103B no module software update is required If the module was introduced after the LXI chassis was manufactured the module may not be recog...

Page 41: ...24 RL21 RL22 RL31 RL32 RL35 RL36 RL33 RL34 RL43 RL44 RL47 RL48 RL45 RL46 RL126 RL123 RL125 RL122 RL119 RL118 RL117 RL116 RL111 RL104 RL103 RL102 RL101 RL108 RL110 RL107 pickering RL121 RL124 RL120 RL1...

Page 42: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Reviews: