Piazzetta MA271 SL Installation Manual Download Page 1

Engl

ish

29

H07025720 / DT2000722 - Rev. 03

Dear Customer,
Thank you for having chosen one of our products, which is the result of years of experience and continuous research aimed at making a
superior product in terms of safety, reliability and performance.
This booklet contains information and advice for safe and efficient use of your product.

DT2010001-01

See the guarantee certificate enclosed with the product for the terms, limitations and exclusions.

In line with its policy of constant product improvement and renewal, the manufacturer may make changes without notice.

This document is the property of Gruppo Piazzetta S.p.A.; no part of it may be disclosed to third parties without the written permission
of Gruppo Piazzetta S.p.A. 
All rights reserved by Gruppo Piazzetta S.p.A..

This instruction booklet has been prepared by the manufacturer
and is an integral part of the product. In the event of sale or relo-
cation of the product make sure this booklet accompanies it, since
the information contained in it is addressed to the purchaser and
to anyone involved in the installation, use and maintenance of the
product.

Read the instructions and the technical information contained in
this booklet carefully before proceeding with installation, use or
any repairs.

The observance of the instructions and technical information in
this instruction booklet guarantees the safety of persons and pro-
perty; it also ensures more efficient operation and an increased li-
fespan.

Gruppo Piazzetta S.p.A. cannot be held responsible for damage or
injury due to failure to comply with the instructions for installa-
tion, use and maintenance given in this booklet, or due to unau-
thorised alterations or to the use of other than original spare
parts.

Appliance installation and use must conform with the manufac-
turer’s instructions as well as with European and national legisla-
tion and local regulations.

The wall against which the product is to be placed must not be of

wood or any other flammable material. For correct installation it
is also important to maintain safety distances (refer to the section
entitled “

MINIMUM SAFETY DISTANCES

”).

Prior to completing installation of the surround, light the stove
and when it has heated up check that the grate and that the flue
connection is correct.

Check that the floor where the product is to be installed is per-
fectly level.

Do not fix the heater unit in any way whatsoever, but simply place
it next to the surround.

When handling the steel parts of the surround or the ceramic
parts it is advisable to use clean cotton gloves to avoid leaving fin-
gerprints that are difficult to remove at first time of cleaning

The fireplace must be assembled by two persons.

This appliance has been designed solely for heating. It is not re-
commended for cooking foods.

Stop using the product in the event of fault or malfunctioning.

The product you have purchased may differ slightly from the one
illustrated in this booklet since the pictures are only given as an
indication and not an exact portrayal.

UNI EN 832  . . . . . . . . . . . . . . . . . . . . . . . .Thermal performance of buildings - Calculation of energy use for heating 
UNI EN 13229  . . . . . . . . . . . . . . . . . . . . . .Inset appliances including open fires fired by solid fuels - Requirements and test methods
UNI 10683:2005 . . . . . . . . . . . . . . . . . . . . .Heating appliances fired by wood or other solid biofuels - Installation requirements
UNI EN 13384  . . . . . . . . . . . . . . . . . . . . . .Chimneys - Thermal and fluid dynamic calculation methods 
UNI 7129  . . . . . . . . . . . . . . . . . . . . . . . . . .Gas plants for domestic use fed by network distribution
UNI 10847  . . . . . . . . . . . . . . . . . . . . . . . . .Chimneys for generators feeded with liquid and solid flues - Maintenance and inspection
EN 1856-1  . . . . . . . . . . . . . . . . . . . . . . . . .Chimneys - Requirements for metal chimneys - Part 1: System chimney products
EN 1856-2  . . . . . . . . . . . . . . . . . . . . . . . . .Chimneys - Requirements for metal chimneys - Part 2: Metal liners and connecting flue pipes
UNI EN 1443  . . . . . . . . . . . . . . . . . . . . . . .Chimneys – General requirements
DIN 18 895 . . . . . . . . . . . . . . . . . . . . . . . . .Fireplaces
DIN 51731 class of measurement HP2    . .Fuels

IMPORTANT INFORMATION

DT2010139-00

REFERENCE STANDARDS

DT2010140-02

Summary of Contents for MA271 SL

Page 1: ...national legisla tion and local regulations The wall against which the product is to be placed must not be of wood or any other flammable material For correct installation it is also important to main...

Page 2: ...8 DIMENSIONS MA283 DX SL 44 2 9 DIMENSIONS MA283 SX SL 44 3 0 PREPARING FOR INSTALLATION 45 4 0 INSTALLATION OF THE SMOKE REGISTER 46 5 0 USE 47 5 1 FUEL 47 5 2 SMOKE DAMPER REGULATION 48 5 3 COMBUST...

Page 3: ...ce according to the indications given in the paragraph MINIMUM SAFETY DISTANCES and to all the indications below DT2031171 00 SOOT REMOVAL INSPECTION HOLE CHIMNEY STACK FLUE CONNECTION TO FLUE SAFETY...

Page 4: ...sections must have rounded corners with a radius of at least 20mm and a maximum ratio between the sides of 1 5 Fig 3 4 5 the walls must be smooth if possible and without narrowing Bends must be regula...

Page 5: ...he distances given below 6 8 metres from any buildings or other obstacles that are higher than the chimney stack 50 centimetres higher than any obstacles located at a distance less than 5 metres outsi...

Page 6: ...re flowing into the room through the canopy grille with ducting through pipes direct to the room of installation in creasing the recommended minimum free cross section by at least 15 from an adjacent...

Page 7: ...drooms in bathrooms or shower rooms DT2010171 00 1 6 CAPACITY LOAD OF THE FLOOR Check the load bearing capacity of the floor by adding together the weight of the protections lining walls insulating ma...

Page 8: ...A between the stove and the lining wall Fig 15 16 NON FLAMMABLE WALLS always leave a gap of 5 cm between the stove and the lining wall CEILING FLAMMABLE CEILING create an 8 cm false ceiling of non fl...

Page 9: ...narrowing or restrictions and with a maximum slope of 45 Flexible metal or asbestos cement pipes must not be used Pipes and bends or elbows must be made in compliance with current regulations WARNINGS...

Page 10: ...he natural convection sy stem and it is therefore necessary to maintain the safety distances from flammable materials such as flammable ceilings or walls led ges beams furniture curtains etc The hood...

Page 11: ...or inflammable material such as beams wooden furniture curtaining flam mable liquids etc be kept outside the heat radiation range of the stove and at a distance of at least 1 5m from the heating block...

Page 12: ...not overload floors or make transportation difficult 8 9 7 1 2 4 5 6 2 4 3 10 MA271 SL DT2033357 00 No Description Qty 1 Enamelled fireplace MA271 SL 1 2 Grate 422x466 2 3 Aluker back panel 495x520 1...

Page 13: ...nt up to 750 C Smoke outlet top Primary air control adjustable manually Secondary air control calibrated Heating natural convection DT2011543 00 2 4 PRODUCT IDENTIFICATION DATA Every product is identi...

Page 14: ...0 Consumption at rated heat output kg h 4 5 4 5 4 5 Thermal efficiency 70 70 70 CO content with 13 O2 Approved in accordance with standard EN 13229 EN 13229 EN 13229 Test report No Flue diameter cm 25...

Page 15: ...H07025720 DT2000722 Rev 03 DT2033359 01 2 6 DIMENSIONS MA271 SL 12 51 64 15 142 25 16 44 53 5 6 59 5 97 49 5 5 138 DT2033573 00 2 7 DIMENSIONS MA272 SL 135 3 25 131 3 59 91 6 10 5 91 11 102 12 5 51 63...

Page 16: ...025720 DT2000722 Rev 03 DT2033360 00 2 9 DIMENSIONS MA283 SX SL 12 51 64 8 135 79 25 17 17 41 51 7 58 90 6 96 53 5 131 DT2033361 00 2 8 DIMENSIONS MA283 DX SL 12 51 64 8 135 79 25 17 17 41 51 7 58 90...

Page 17: ...ch is con tained in the supplied accessoires kit Adjust the height of the fireplace from the ground according to the chosen cladding or surround If more height is needed insert sui table shims If a PI...

Page 18: ...and its con nection to the flue as indicated in the section with the same name Construct or finish the preparation of the lining and of the facing wall Insert the wooden plug provided into the box 4 a...

Page 19: ...ady to burn must have been dried in the open air sheltered from rain or snow for at least 2 years after having been cut The lower the moisture content of the wood the higher its heating power Freshly...

Page 20: ...may vary according to the atmospheric conditions the type of flue and consequently the draught You will learn by trial and error which is the best position for the smoke damper Should the flue have a...

Page 21: ...e allows all the parts to settle down and fumes caused by paints varnishes greases or oily liquids used in manufacture to dis appear Air the room well in this initial stage This procedure must be carr...

Page 22: ...wo centimetres for 5 10 minutes once a bed of embers has formed stoke up as recommended and adjust the air dampers and the smoke damper if installed as de scribed in the paragraphs COMBUSTION AIR REGU...

Page 23: ...h before applying any detergents Afterwards it is recommended that you use a degreasing agent such as acetone or vinegar diluted in water DT2010059 03 6 2 CLEANING THE CERAMIC CLADDING The ceramic cla...

Page 24: ...eplace them using Gruppo Piazzetta S p A original spare parts DT2010063 00 6 8 CLEANING THE GRATE AND THE ASH TRAY The grate and the ash tray must be cleaned daily Using the grate for a whole day cont...

Page 25: ...ce for optimum use of Aluker bricks Don t use water to put out the fire leave the bricks to cool by themselves Don t scratch Aluker bricks with metal objects To clean Aluker bricks use an ordinary bru...

Page 26: ...Use dry wood Use of mediocre or poor class fuels Change the type of fuel See FUEL paragraph Not enough combustion air Open the air dampers further Condensation forms Section of flue too large Reduce...

Page 27: ...ate for the environment to be heated Integrate with another product Inadequate insulation for the environ ment in which the fireplace is installed Insulate well with suitable materials Oversized fresh...

Page 28: ...o TV ITALY Tel 39 04235271 Fax 39 042355178 www piazzetta it e mail infopiazzetta piazzetta it N matricola prodotto da comunicare al Centro Assistenza Tecnica del Gruppo Piazzetta in caso di richiesta...