Piazzetta 2010 HT/B Instructions For Installation, Use And Maintenance Manual Download Page 1

H07020830 / DT2000269-04

2010 HT/B

Italiano

MONOBLOCCO

FIREPLACE

ISTRUZIONI PER L’INSTALLAZIONE, L’USO E LA MANUTENZIONE

INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE

Il libretto istruzioni è parte integrante del prodotto.

 - 

The instruction booklet is an integral part of the product.

English

Summary of Contents for 2010 HT/B

Page 1: ...NOBLOCCO FIREPLACE ISTRUZIONI PER L INSTALLAZIONE L USO E LA MANUTENZIONE INSTRUCTIONS FOR INSTALLATION USE AND MAINTENANCE Il libretto istruzioni parte integrante del prodotto The instruction booklet...

Page 2: ...ioni garantisce la sicurezza alle persone e cose assicura l economia di esercizio ed una pi lunga durata di funzionamento Il Gruppo Piazzetta S p A declina ogni responsabilit per danni causati dalla i...

Page 3: ...unzionamento notturno al minimo 23 5 8 Funzionamento in condizioni atmosferiche avverse 24 5 9 Surriscaldamento e spegnimento 24 6 0 MANUTENZIONE 25 6 1 Controllo periodico 25 6 2 Pulizia del rivestim...

Page 4: ...VERIFICA PORTATA SOLAIO MODALIT DI DIFFUSIONE DEL CALORE COMIGNOLO CONTROPARETE PROTEZIONE TRAVE APERTURA FISSA DISTANZE MINIME DI SICUREZZA GRIGLIA DI CAPPA 1 0 NORME GENERALI Prima di procedere con...

Page 5: ...uniforme preferibilmente circolare le sezioni quadrate o rettangolari devono avere spigoli arrotondati con raggio non inferiore a 20 mm avente un rapporto massimo tra i lati di 1 5 Fig 3 4 5 le pareti...

Page 6: ...e in atmosfera dei prodotti della combustione importante che il comignolo rispetti le distanze qui riportate 6 8 metri lontano da eventuali fabbricati od altri ostacoli che su perano l altezza del com...

Page 7: ...l aria possa riscaldarsi prima di fluire nell ambiente Fig 12 con una canalizzazione tramite dei tubi diretti all ambiente di installazione maggiorando la sezione minima libera indicata di almeno il 1...

Page 8: ...affidarsi ad un termotecnico vedi NORMATIVE DI RIFERIMENTO I prodotti con il sistema Multifuoco a parit di potenza nominale possono distribuire in modo omogeneo il calore nei locali da riscaldare 1 5...

Page 9: ...ci posti sulla parte superiore del mono blocco Fig 15 non devono in alcuna maniera essere ostruiti per mettendo in tal modo il regolare funzionamento del Multifuoco Sy stem ed il regolare deflusso del...

Page 10: ...torno alla griglia di uscita aria calda necessario mantenere una zona di sicurezza all interno della quale vietata la presenza di oggetti infiammabili mobilio tappeti tende La zona di sicurezza compre...

Page 11: ...rmico Fig 22 La distanza minima tra controsoffitto e collegamento alla canna fumaria deve essere di 20 cm isolando il collegamento alla canna fumaria con materiale non infiammabile ed indeformabile al...

Page 12: ...urve del Gruppo Piazzetta S p A in quanto lo scarico fumi del prodotto dimensionato per l innesto di questi inoltre rispettano i requisiti richiesti dalle norme Possono essere applicati anche altri tu...

Page 13: ...convezione naturale dalla griglia di cappa esce aria calda quindi necessario mantenere le distanze di sicurezza da materiali infiammabili quali soffitti o pareti infiammabili travi mobili tendaggi ecc...

Page 14: ...necessario applicare modalit di in stallazioni particolari protezione isolamento termico distanze da materiali sensibili al calore ecc Fare riferimento al paragrafo Collegamento alla canna fumaria Si...

Page 15: ...utti i monoblocchi sono dotati di mantello cappa un cappuccio metallico che avvolge e ricopre la struttura della cappa del caminetto e consente un maggior recupero di calore all aria Collegando dei tu...

Page 16: ...ione l asportazione la mancanza della Targhetta Tec nica rende difficoltosa qualsiasi operazione di installazione e ma nutenzione dalla mancanza di identificazione del prodotto In caso di danneggiamen...

Page 17: ...rtata fumi g s Temperatura media dei fumi nel tubo di scarico C Tiraggio minimo Pa Questi dati sono ottenuti utilizzando legna di faggio con umidit inferiore al 20 ad intervalli per ogni singola ricar...

Page 18: ...legate al kit e fare riferimento al paragrafo Modalit di diffusione del calore Regolare l altezza del monoblocco da terra operando sui piedini del camino in relazione al rivestimento prescelto portare...

Page 19: ...della controparete Inserire il tassello in legno in dotazione nella scatola 4 ed infi larla nell asta 1 Determinare quindi l esatta posizione della scatola che deve se guire l inclinazione della contr...

Page 20: ...ERE CALORIFICO DELLA LEGNA Faggio Valori indicativi E buona norma acquistare la legna durante il periodo estivo giugno luglio in quanto i tagli dei boschi si eseguono prevalentemente in autunno quindi...

Page 21: ...fumaria e non come ultimo in quinare la natura 5 2 Regolazione del registro fumi Fig 39 2010 HT B APERTO CAMINETTO ALL ACCENSIONE O QUANDO SI CARICA POSIZIONE REGISTRO CAMINETTO IN FUNZIONE ALLA POTE...

Page 22: ...zionamento verificare che tutto sia installato in modo corretto vedi capitolo NORME GENERALI Iniziare con la fase di accensione vedi paragrafo Accensione La prima carica nominale va ridotta del 50 In...

Page 23: ...o fuoco ci sono solo le braci Aprire la porta quando le fiamme sono vive o intense rischioso sia per l utente che per l abitazione L apertura della porta va fatta lentamente tenendola per qualche seco...

Page 24: ...e in modo che la legna presente sul focolare arda pi velocemente stabilizzando cos il tiraggio 5 9 Surriscaldamento e spegnimento In caso di surriscaldamento arrossamenti di alcune parti dell apparecc...

Page 25: ...di evacuazione fumi collegamento alla canna fumaria canna fumaria comignolo la presa d aria esterna il focolare dell apparecchio corretto posizionamento delle piastre del cassetto cenere del piano fu...

Page 26: ...ve essere posta in un contenitore in metallo con coperchio a tenuta Fino allo spegnimento definitivo delle braci il contenitore chiuso deve essere posto su una base non combustibile e ben lontano da m...

Page 27: ...del prodotto per un lungo periodo consigliamo di pulire completamente il focolare onde evitare incrostazioni e ossidazioni difficili da pulire e di effettuare a titolo preventivo un controllo generale...

Page 28: ...re legna secca Utilizzo di combustibili di classe mediocre o cattiva Cambiare il tipo di combustibile vedi paragrafo Combustibili Poca aria comburente Aprire in maggior misura i registri aria se prese...

Page 29: ...ottenere la resa nominale Usare la quantit di legna indicata nelle istruzioni vedi paragrafo Dati tecnici Focolare sottodimensionato per l ambiente da riscaldare Integrarlo con un altro prodotto Isola...

Page 30: ...re Pulire il ventilatore Vibrazioni Controllare il posizionamento del ventilatore Usura delle parti rotanti Sostituire il ventilatore Uscita fumi all apertura dell anta Apertura troppo veloce Tenere l...

Page 31: ...H07020830 DT2000269 04 31...

Page 32: ...of the instructions and technical infor mation in this instruction booklet guarantees the safety of persons and property it also ensures more efficient ope ration and an increased lifespan Gruppo Pia...

Page 33: ...first time 52 5 5 Lighting 53 5 6 Opening the door 53 5 7 Night time operation at minimum 53 5 8 Operation under adverse weather conditions 54 5 9 Overheating and extinguishing 54 6 0 MAINTENANCE 55 6...

Page 34: ...A GRIGLIA DI CAPPA 1 0 GENERAL RULES Before proceeding with installation choose the most suitable position for your fireplace according to the indica tions given in the paragraph MINIMUM SAFETY DISTAN...

Page 35: ...bly round Square or rectan gular sections must have rounded corners with a radius of at least 20 mm and a maximum ratio between the sides of 1 5 Fig 3 4 5 the walls must be smooth if possible and with...

Page 36: ...any case well insulated It must be built in such a way as to prevent the penetration of rain snow and foreign matter into the flue and to ensure that in the event of winds from all directions and ang...

Page 37: ...re may be obtained in different ways through a fresh air intake direct into the room of installation we kindly advise you to place the air intake behind the firebox so that the air warms up before cir...

Page 38: ...onsult a heating technician or engineer for a correct check and calculation of the requirement of the environ ments to be heated see REFERENCE STANDARDS Ratedpowerbeingequal productswiththeMultifuocoS...

Page 39: ...ow proper operation of the Multifuoco System and the regular outflow of the warm air that stratifies inside the internal hood and comes out the hood grilles For the size of the hood grille see the Tec...

Page 40: ...ludes 600 mm from the outer edge of the grille Figure 19 1 9 Suitable heat insulating materials Type of suitable heat insulating materials Material mineral fibre ceramic fibre rock wool Form sheets ma...

Page 41: ...th at least 3 cm thick non flammable material that is resistant to high temperatures If the surround canopy and the flue connection are metal the mi nimum distance from the false ceiling may be reduce...

Page 42: ...sized to fit the flue outlet of the appliance and are also in compliance with regulations and standards Other pipes may be applied after adaptation and checking of the compatibility of the coupling ta...

Page 43: ...atural convec tion system and it is therefore necessary to maintain the safety distances from flammable materials such as flammable ceilings or walls ledges beams furniture curtains etc The hood grill...

Page 44: ...special installation methods must be applied protection thermal insulation distances from heat sensitive materials etc See the paragraph Connection to the flueway It is also recommended that all elem...

Page 45: ...R D Department All the fireplace are fitted with a metal hood that wraps around and covers the fireplace canopy and allows a greater recovery of heated air By connecting hoses to the holes on the meta...

Page 46: ...e is missing has been removed or tampered with any installation and maintenance operations are made difficult due to lack of product identification In the event of damage please ask the Piazzetta afte...

Page 47: ...Combustion air flow rate with open intake m3 h Convective air inlet outlet recommended minimum section cm2 350 350 2010 HT B Rated heat output kW 14 0 Smoke flow rate g s 16 8 Average temp of smoke in...

Page 48: ...tem ventilation kit if envisaged following the indications given in the respective instructions and refer to the paragraph Methods of heat diffusion Adjust the height of the grate working on the feet...

Page 49: ...he lining and of the facing wall Insert the wooden plug provided into the box 4 and thread it onto the rod 1 Then determine the exact position of the box which must follow the angle of the facing wall...

Page 50: ...he wood beech Approximate value It is a good rule to purchase timber during the summer June July since woods are cut down mostly in the autumn and you can the refore be sure that the timber has alread...

Page 51: ...nnection and the flue and last but not least pollute the environment 5 2 Smoke damper regulation Fig 39 2010 HT B OPEN LIGHTING OR STOKING UP OF FIREPLACE SMOKE DAMPER POSITION FIREPLACE IN OPERATION...

Page 52: ...ating test and start up 1 Operating test Before carrying out the operating test check that everything has been installed correctly see section GENERAL RULES Start with the lighting stage see paragraph...

Page 53: ...ight the soft wood quickly open the door by approx two centimetres for 5 10 minutes Figure 41 2 Once the bed of embers has been created stoke up with the recommended amounts of fuel Keep the door clos...

Page 54: ...by stabilises the draught In the event of fire extinguish with a fire extinguisher 5 9 Overheating and extinguishing In the event of overheating or if some appliance parts or the flue turn red immedia...

Page 55: ...sing serious damage to both the flue and to the structure of the dwelling Only use recommended fuels see Fuel paragraph If creosote has accumulated it must be removed to reduce the risk of fire and to...

Page 56: ...e lighting the stove The glass should be cleaned when cold using ammonia based degreasing agents and not corrosive substances such as solvents Do not use any material that could scratch or spoil the g...

Page 57: ...osing system must be checked periodically at least once every two years attention must be paid in particular to lubricating the roller located inside the double glazing or depending on the model the p...

Page 58: ...ively dirty Lack of draught Open the smoke damper Check the smoke gas discharge pipe Wet wood Use dry wood Use of mediocre or poor class fuels Change the type of fuel See Fuel paragraph Too little com...

Page 59: ...er product Inadequate insulation for the environment in which the fireplace is installed Insulate well with suitable materials Oversized fresh air intake Decrease the intake section The fan does not w...

Page 60: ...ruction booklet contains all the useful information for installation operation and maintenance Only call the Gruppo Piazzetta S p A service centre after having scrupulously followed all the instructio...

Page 61: ...H07020830 DT2000269 04 COPIA COPY 61...

Page 62: ...H07020830 DT2000269 04 62...

Page 63: ...H07020830 DT2000269 04 63...

Page 64: ...azzetta piazzetta it Gruppo Piazzetta S p A Technical Department Cod H07020830 DT2000269 rev 03 11 2014 N matricola prodotto da comunicare al Centro Assistenza Tecnica del Gruppo Piazzetta in caso di...