10 Technical Data
V-273 VC Linear Actuator
MP124E
Version: 1.0.0
35
10.1.2 Maximum Ratings
The voice coil drive of the V-273 linear actuator is designed for the following operating
data:
Maximum
Operating Voltage
Maximum Operating
Frequency
Maximum Power
Consumption
48 V
24 W
10.1.3 Ambient Conditions and Classifications
The following ambient conditions and classifications must be observed for the V-273:
Area of application
For indoor use only
Maximum altitude
2000 m
Air pressure
1100 hPa to 795 hPa
(corresponds to roughly 825 Torr to 596 Torr)
Relative humidity
Highest relative humidity 80 % for
temperatures up to 31 °C
Decreasing linearly to 50 % relative humidity
at 40 °C
Operating temperature
10°C to 60°C
Storage temperature
-20 °C to 60 °C
Transport temperature
-20 °C to 60 °C
Overvoltage category
II
Protection class
I
Degree of pollution
1
Degree of protection
according to IEC 60529
IP20