S5/S7-TimeServer

user manual

V1.00

English

User manual compatible with software V1.00 or higher!

© Copyright by PI 2022

Summary of Contents for S5-TimeServer

Page 1: ...S5 S7 TimeServer user manual V1 00 English User manual compatible with software V1 00 or higher Copyright by PI 2022...

Page 2: ...elements 9 4 1 status LEDs 9 4 2 buttons 10 4 3 web server 11 4 3 1 page structure 11 4 3 2 access protection 12 4 3 3 page stations 13 4 3 3 1 list with stations 14 4 3 3 2 settings of a station 15 4...

Page 3: ...5 Technical data 30 page 3 manual S5 S7 TimeServer V1 00...

Page 4: ...s which can be used for small controlling and messaging tasks additionally to the function as a time server This documentation can be downloaded on the web page of the product via downloads documentat...

Page 5: ...e for intended purpose The devices are constructed for the mounting and usage in weatherproofed indoor places The operating conditions which are named in this documentation have to be followed The ope...

Page 6: ...the device via WLAN you will have to screw the WLAN antennas to the SMA connectors of the device and make sure that your PC is in the range from the device 2 2 Software If you want to access the web s...

Page 7: ...re that the WLAN interface of your laptop or tablet is enabled Then you should open the list with available WLAN networks There you should now see a WLAN network with the SSID RUT955_ The exact SSID a...

Page 8: ...IP address 192 168 1 1 into the address line Now you should see the start page of the device There you will now be able to configure the PLC stations where you want to do a time adjust The descriptio...

Page 9: ...w the bars are showing up the signal strength This means the more LEDs are light up the better the signal is The LED directly below the mobile symbol is a multi color LED and gives more information ab...

Page 10: ...tton can be individually configured on the web interface from Teltonika From factory default the following actions are executed depending on the time span where the button is pressed min time max time...

Page 11: ...ets displayed on the left side If you want to navigate to one page you just have to click on the desired entry If you want to hide the menu you only have to click on the icon or text menu again The we...

Page 12: ...sed directly If you have configured a password you will be queried to enter a password with the following dialog After you have entered the password and clicked on log in you will be redirected to the...

Page 13: ...s configuration of the PLC stations where a time adjust should be executed On the page you can see on the upper right corner the current system time of the device and in the middle the list of station...

Page 14: ...rrent state or last result as well as the last time of the time adjust in the second line Further information about the current state can be found in the diagnosis dialog On the right side of the entr...

Page 15: ...nnection to the PLC rack number The number of the rack where the PLC is connected to default 0 slot number The number of the slot where the PLC is connected to default 2 for S5 or S7 200 300 400 or 1...

Page 16: ...r The number of the data block where the time should be written to block offset The offset in bytes within the data block where the time should be written to If you want to submit the changes you will...

Page 17: ...time active Bit 0 0 DB15 time adjust executed Bit 0 1 Hint The bit time adjust executed within the formats of DB binary and DB ASCII can be used from the PLC to determine if the S5 S7 TimeServer has u...

Page 18: ...can trigger a time adjust for this station manually This button has the same effect as the symbol in the list 4 3 4 page configuration On the configuration page menu item configuration you have the po...

Page 19: ...ibility to configure the password which is needed for accessing the web interface of the device If you want to change the password you have to enable the change password box and enter your old passwor...

Page 20: ...have any problems with your device Important If you set your device to factory defaults all settings of the device will be lost 4 3 4 4 date and time The group date and time contains a few general se...

Page 21: ...mode The device is reachable via the specified address client The device refers an IP address from a DHCP server server The device is reachable via the specified address and provides IP addresses to o...

Page 22: ...server if you don t want that the S5 S7 TimeServer offers IP address to other network participants Important Within the delivery status from the S5 S7 TimeServer the device offers an own WLAN network...

Page 23: ...ace deactivate WLAN Specifies if the WLAN interface should be disabled or not interface Specifies if the interface should be used MAC address The MAC address of the interface this value can t be chang...

Page 24: ...an existing WLAN network SSID The SSID name of the WLAN network security type The security type encryption of the WLAN network password The password which is needed for logging in to the WLAN network...

Page 25: ...annel is least charged Therefore the device can show you the channel work load This can be done by clicking on the icon behind the channel selection list After clicking on the search icon a load symbo...

Page 26: ...needed for logging in to the WLAN network hide SSID Specifies if the SSID should be hidden Hint The WLAN and WLAN AP settings from the device are completely independent of each other Only the global...

Page 27: ...he web page periodically in the background If the automatically re connection does not work within about 1 minute please check that the computer is connected with the correct interface Please do also...

Page 28: ...e On this page you can see your current version of the device and have the possibility to select a file After you have selected a software file this is a file with the extension ipk you can click on t...

Page 29: ...verified as valid software you will see the following message The update process takes about 1 2 minutes If the process has completed you should be redirected to the start page automatically page 29 m...

Page 30: ...enna connector SMA f GNSS GPS 1 x RS485 port via plug connector 1 x RS232 port via D Sub 9 pols female 2 x digital input 1 x 0 3V 1 x 0 30V 1 x analog input 0 24V 1 x digital output open collector 30V...