10 Technical Data
PL0xx/PDxxx Piezo Actuator
PZ265E
Version: 1.0.0
53
10.1.4
Ambient Conditions and Classifications
The following ambient conditions and classifications for the PL0xx/PDxxx must be observed:
Area of application
For indoor use only
Air pressure
500 hPa to 1500 hPa
If you want to operate the PL0xx/PDxxx outside of the
specified air pressure range, contact our customer service
department (p. 47).
Relative humidity
Maximum relative humidity 55 %
Continuous operation with high static voltage in humid
environments significantly reduces piezo actuator lifetime.
If you want to operate the PL0xx/PDxxx at a relative
humidity of more than 55 %, contact our customer service
department (p. 47).
Observe the information on service life, which can be found
here:
−
Section "General Notes on Start-Up and Operation"
(p. 31)
−
Internet site of PI Ceramic (www.piceramic.com/piezo-
Operating temperature
–40 °C to 150 °C
Storage temperature
–40 °C to 80 °C
Transport temperature
–40 °C to 80 °C
Overvoltage category
II
Degree of pollution
1
The PL0xx/PDxxx is intended for installation in devices that fulfil the following classifications:
Protection class
I
Degree of protection
according to IEC 60529
IP20