User Manual
P603T0001, valid for P-603
CBo, 1/11/2021
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany
Page 13 / 21
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email
Requirements
You have read and understood the safety precautions (p. 6).
You have provided a suitable underlying surface for mounting the P-603:
-
The surface is connected to a protective earth conductor (p. 12).
-
The surface has two suitable through holes. Refer to “Dimensions” (p. 19) for
details.
-
The holes for the screws are sufficiently conductive to ensure that the protective
earth conductor functions properly.
-
The flatn
ess of the surface is ≤
40 µm.
You have discharged the P-603 (p. 14).
Tools and accessories
Two M2.5 screws of suitable length (p. 19) for mounting the actuator onto a surface
Two M2.5 screws of suitable length (p. 19) for mounting a load to the actuator
Suitable tools
Mounting the P-603 and mounting a load
1.
Only mount the P-603 onto a surface using the mounting holes intended for this purpose
Maximum torque: 0.7 Nm
2.
Only fix a load to the P-603 using the mounting holes intended for this purpose (refer
Maximum torque: 0.5 Nm
Startup and Operation
Starting and Operating the P-603
Requirements
You have read and understood the safety precautions (p. 6).
Starting and operating the P-603
Follow the instructions in the user manual for the electronics used for startup and
operation of the P-603.