8 GCS Commands
150
Version: 1.2.1
MS249E
C-863.12 Mercury Controller
Arguments:
<RecTableID> is one data recorder table of the controller.
See below for details.
<TriggerSource> ID of the trigger source, see below for a
list of available options.
<Value> depends on the trigger source, can be a dummy,
see below.
Response:
none
Notes:
At present, only 0 is valid for <RecTableID>; this means
that the specified trigger source is set for all data recorder
tables that have a record option that is not zero.
Irrespective of the trigger option set, data recording is
always triggered when step response measuring is done
with STE (p. 194).
With HDR? (p. 157), you will obtain a list of all available
record and trigger options and additional information on
the data recording.
For further information, see the description of the DRC
command (p. 145) as well as "Data Recorder" (p. 74).
Available trigger
options:
0 = default setting
Data recording is triggered by STE; <Value> must be a
dummy.
1 = any command changing target position
e.g., MVR (p. 179), MOV (p. 177); <Value> must be a
dummy.
2 = next command
resets trigger after execution; <Value> must be a dummy.
6 = any command changing target position, reset trigger
after execution
e.g., MVR, MOV; resets trigger after execution; <Value>
must be a dummy.
DRT? (Get Data Recorder Trigger Source)
Description: