3 Product Description
M-230 Linear Actuators
MP102E
Version: 1.2
11
3.5 Scope of Delivery
Order
Number
Items
M-230
Linear actuator according to order (p. 9), with flat tip (assembled on
delivery), spherical tip and hook wrench
MP122EK
Short instructions
3.6 Suitable Controllers
The M-230 must be connected to a suitable controller (see Data Table, p. 33).
The required PC software is included in the scope of delivery of the controllers from
PI. The operation of the controllers is described in the corresponding user manuals.
3.7 Accessories
Order Number
Description
C-842.AP1
Adapter box PWM analog to operate M-230 linear actuators with
PWM signals
To order, contact our customer service department (p. 31).
3.8 Technical Features
3.8.1 Rotary Encoder
The models with DC motors are equipped with a rotary encoder. A rotary encoder,
also called an incremental or incremental rotary encoder, is implemented at a rotating
point in the drivetrain, e.g. the motor shaft. To determine the relative position, the
controller counts the encoder signals, the so-called impulses.
3.8.2 Limit Switches
The M-230 is equipped with non-contact, Hall-effect limit switches.
Each limit switch sends an overtravel signal on a dedicated line to the controller. The
controller then stops the motion. If the controller does not stop the motion in time, the
linear actuator runs into the hard stop.
See "Limit Switch Specifications" (p. 35) for more information.