background image

 

2 INTRODUCTION

Radioactivity is a subject in our society which has been

playing an important role throughout politics, economy and

media for many years now. The fact that this radiation cannot

be seen or felt by the human being and that the effects of this

radiation are not fully explored yet, causes emotions like no

other scientific subject before.

The high-performance diffusion cloud chamber by PHYWE

Systeme GmbH & Co. KG serves for making the tracks of

cosmic and terrestrial radiation visible so that a wide range of

natural radiation types can be identified. Furthermore, the

diffusion cloud chamber offers the opportunity to carry out

physical experiments with the aid of artificial radiation

sources.

3 DESIGN AND OPERATION

The cloud chamber consists of a chamber base and the

observation chamber. The chamber base comprises a

cooling element, a power supply, an alcohol reservoir, an

alcohol pump and a programmable time switch. The

observation chamber is placed onto the chamber base.

The bottom of the observation chamber is formed by a

massive, black metal plate (surface 45 cm x 45 cm) which is

cooled over the whole surface to about -30°C by means of

the cooling element.

The top plate and the side plates of the observation chamber

consist of two glass hoods which are placed one into the

other. A grid of fine heating wires (

17

) is placed between the

upper two glass plates. These wires serve for heating this

area of the chamber thus keeping the hood free from

condensation. At the same time they are held at high voltage

thus generating an electric field that attracts the ions.

09046.90... 99

Diffusion cloud chamber PJ45

09046.90… 99/0709

1  SAFETY PRECAUTIONS

• Carefully read these operating instructions completely

before operating this instrument. This is necessary to avoid

damage to it, as well as for user-safety.

• Only use the instrument for the purpose for which it was

designed.

• Check that your mains supply voltage corresponds to that

given on the type plate fixed to the instrument.

• Only use the instrument in dry rooms in which there is no

risk of explosion.

• Do not operate the system when obvious damages or leaks

are visible.

• Install the instrument so that the on/off switch and the

mains connecting plug are easily accessible. Do not cover

the ventilation slots.

• Only use an extension cable or a multiple socket when

absolutely necessary.

• Wait at least 2 hours before putting the cloud chamber into

operation to check that no faults have occurred to the

refrigeration system during transport.

• Always unplug the mains plug before carrying out cleaning

or maintenance work.

PHYWE Systeme GmbH & Co. KG
Robert-Bosch-Breite 10
D-37079 Göttingen

Phone

+49 (0) 551 604-0

Fax

+49 (0) 551 604-107

E-mail

[email protected]

Internet www.phywe.de

Operating instructions

www.phywe.de, © All rights reserved

 

1

Fig. 1: Diffusion cloud chamber PJ45, 09046.93.

The unit complies 

with the corresponding

EC guidelines.

Reviews: