Disconnect the charger at the latest four hours af-
ter the completion of the charging process.  Other-
wise,  the  service  life  of  the  battery  may  be  nega-
tively affected. 

 

5.2  Start-up 
 
Use without software / App 

Switch on the sensor by pressing and holding the power but-
ton for more than 3s. The start screen is now displayed. 
 
 
  
 
 
 
 
 
 
 
 
A measurement can be started (    ) or stopped (    ) by press-
ing the power button     . 
 
Press the arrow keys          to access the selection of modes 
or  settings.  The  modes  are  also  confirmed  by  pressing  the 
power button      . 
 
The following modes can be selected: 
 

Mode 1 

Speed 

Dual Photogate 

Mode 2   Counter 

Dual Photogate / Laser 

Mode 3 

Acceleration 

2x Dual Photogate 

Mode 4 

Distance 

Grating 

Mode 5 

Shading time 

Dual Photogate / Laser 

 
 

Measured value recording 

A measurement can be started (    ) or stopped (    ) by press-
ing the power button     . 

 
 
Use with software / App 

Switch the sensor on by pressing the on-button for more than 
3  seconds.  The  Bluetooth  LED  lights  up  red.  Start  the 
measureApp application and select the sensor. 
 
A  9-digit  code  is  printed 
on the back of the sensor 
(Fig.6).  The  last  4  digits 
of the code are displayed 
as  sensor  designation  in 
the software (Fig.7). This 
enables 

an 

exact 

assignment 

of 

the 

sensors 

with 

the 

software.    

 

 

    

 

 

 

 

Fig. 6 

 
 
 

   

 

 

 

   

 

 

   

  

 

Fig. 7 

 

Selection of the sensor via the Bluetooth interface 

Make  sure  that  the  Bluetooth  interface  is  activated  on  the 
terminal  device  (PC/Tablet/Smartphone)  and  that  the  soft-
ware is allowed to access the interface.  
 
After the sensor has been selected in the software, the LED 
flashes green to indicate that the connection has been estab-
lished  correctly.  After  the  sensor  has  been  coupled  with  the 
software, the sensor is no longer visible to other users in the 
software, and therefore can no longer be selected.  
 
If the sensor is switched on and not connected, it switches off 
automatically after 5 minutes. 
 

Selection of the sensor via the USB interface 

For  this  purpose  the  sensor  must  be  plugged  into  the  USB 
port  of  the  end  device.  It  is  not  necessary  to  switch  on  the 
sensor.  The  sensor  is  automatically  recognized  and  dis-
played. It can be selected and connected directly. 

6  TECHNICAL DATA  

Operating temperature range: 5 - 40°C 
Rel. humidity < 80% 
 
Time: 

 

   Range 
   Resolution       
   Accuracy  
Speed: 
   Range 
   Resolution 
Acceleration: 
   Range 
   Resolution 

0…∞ s 

1 µs 

± 10 µs 

 

± 100 m/s 

0,01 m/s 

 

± 100 m/s

0,01 m/s

2

 

Max. date rate  
Battery capacity 
Max. wireless range (open field) 

100 Hz 

250 mAh 

30 m 

Dimensions (length x width x height) 

130 x 105 x 26  mm 

Weight  

165 g 

7  SCOPE OF DELIVERY 

The scope of delivery 12945-00 includes: 

 

Cobra SMARTsense Dual Photogate 

12945-00 

 

USB-connecting cable type C 

 

RJ-45 connecting cable 

 

2x Grating 

 

Threaded rod (length 10cm) 

 

 

Operating instructions 

 

The scope of delivery 12945-01 includes: 

 

2x knurled screw 

 

 

2x mounting brackets for track mounting 

 

Incremental Base socket (clamping socket) 

 

 

Incremental wheel 

 

Operating instructions 

 

 

 

Measuring mode 

Available light barriers 

From left to right:  
Device A gate 1, gate 2 

Device B gate 1, gate

 2 

Laser receiver 

Bluetooth connection 

Measurement start/stop (         ) 

Summary of Contents for Cobra SMARTsense Dual Photogate

Page 1: ...perating instructions completely before operating this instrument This is necessary to avoid damage to it as well as for user safety Only use the instrument for the purpose for which it was designed Only use the instrument in dry rooms in which there is no risk of explosion Protect the instrument from dust moisture and vapours Use a slightly moist lint free cloth to clean the instrument Do not use...

Page 2: ...lp of the grating continuous data acquisition can be carried out e g for drop tests Fig 3 3 7 Incremental wheel base only in 12945 01 Fit the base to the housing of the photogate using the screw provided Fig 4 and then push the incremental wheel onto the base until a click is heard Fig 5 Fig 4 Fig 5 4 NOTES ON OPERATION This device fulfils all of the technical requirements that are compiled in cur...

Page 3: ...and that the soft ware is allowed to access the interface After the sensor has been selected in the software the LED flashes green to indicate that the connection has been estab lished correctly After the sensor has been coupled with the software the sensor is no longer visible to other users in the software and therefore can no longer be selected If the sensor is switched on and not connected it ...

Page 4: ...ly materials that should be returned to the local recycling sta tions PHYWE Systeme GmbH Co KG Abteilung Kundendienst Robert Bosch Breite 10 D 37079 Göttingen Telefon 49 0 551 604 274 Fax 49 0 551 604 246 Do not dispose of this product with normal household waste If this unit needs to be disposed of please return it to the address that is stated below for proper disposal PHYWE Systeme GmbH Co KG h...

Reviews: