PHYWE Cobra SMARTsense Ammonium Ion 12913-00 Operating Instructions Download Page 5

 

 

 

 

 

 

www.phywe.com, © All rights reserved 

 

12913-00 / 0222

 

10  DISPOSAL 

The  packaging  mainly  consists  of  environmentally-friendly 
materials  that  should  be  returned  to  the  local  recycling  sta-
tions.

 

PHYWE Systeme GmbH & Co. KG 
Abteilung Kundendienst 
Robert-Bosch-Breite 10 
D

–37079 Göttingen 

 
Telefon 

+49

 (0) 551 604-274 

Fax 

+49

 (0) 551 604-246 

Do not dispose of this product with normal 
household  waste.  If  this  unit  needs  to  be 
disposed of, please return it to the address 
that is stated below for proper disposal 

Summary of Contents for Cobra SMARTsense Ammonium Ion 12913-00

Page 1: ...RIES 9 CONFORMITY 10 DISPOSAL 1 SAFETY PRECAUTIONS Carefully read these operating instructions completely before operating this instrument This is necessary to avoid damage to it as well as for user safety Only use the instrument for the purpose for which it was designed Only use the instrument in dry rooms in which there is no risk of explosion Protect the instrument from dust moisture and vapour...

Page 2: ...urs unplug it and plug it back in again for a reset 5 HANDLING This section describes the start up of the sensor and the re cording of measurement data Please read this section thor oughly in order to avoid failures or operating errors 5 1 Start up Switch the sensor on by pressing the on button for more than 3 seconds The Bluetooth LED lights up red Star the soft ware and select the sensor There i...

Page 3: ...0 ml H20 deionised 10 ml 1 M NH4Cl 5 4 Calibration Perform a 2 point calibration using measureAPP Use 160 mg l for the 1st measuring point and 1600 mg l for the 2nd measuring point The calibration solutions are prepared from the stock solutions Use a magnetic stirrer with uniform stir ring speed for uniform mixing Recipe for calibration solutions To prepare 1 litre of calibration solution you will...

Page 4: ...hed to the upper edge Push the battery into the socket by pressing lightly on the oppo site side The battery slips under the two plastic lugs Fig 10 2 which is also noticed by a short click Fig 10 Before closing make sure that the seal in the lid is not bent and lies neatly on the edge of the lid Then tighten the cover clock wise Fig 11 6 TECHNICAL DATA Operating temperature range 5 40 C Relative ...

Page 5: ... returned to the local recycling sta tions PHYWE Systeme GmbH Co KG Abteilung Kundendienst Robert Bosch Breite 10 D 37079 Göttingen Telefon 49 0 551 604 274 Fax 49 0 551 604 246 Do not dispose of this product with normal household waste If this unit needs to be disposed of please return it to the address that is stated below for proper disposal ...

Reviews: