12620-09 and 12620-10 / 2715

 

-

 

Use the experimental set-up solely for the intended pur-
pose. 

-

 

Do  not  open  the  unit.  It  is  not  necessary  to  replace  the 
rechargeable battery. 

-

 

Based  on  today's  state  of  software  development,  it  is 
impossible to guarantee that a product is completely free 
from  errors  or  defects.  This  is  why  PHYWE  Systeme 
GmbH & Co. KG does not accept any liability for damage 
that results from the installation or use of this unit. 

2

 

PURPOSE AND CHARACTERISTICS 

The  Cobra4  Mobile-Link 2  is  used  for  the  mobile  acquisition 
of  measurement  values  that  are  generated  by  way  of  a  Co-
bra4 Sensor-Unit. 

For  this  purpose,  the  unit  is  equipped  with  an  SD/MMC 
memory  card.  The  control  menu  of  the  unit  enables  all  rele-
vant  adaptations,  e.g.  the  calibration  and  taring  of  the  unit, 
without the need for a PC. 

In order to transfer the data to the PC after the completion of 
the measurement, the Cobra4 Mobile-Link 2 is equipped with 
a  USB  socket.  As  an  alternative,  the  memory  card  can  be 
removed and the data can be transferred to a PC by way of a 
reading  device.  Ensure  that  no  other  Cobra4  device  is  con-
nected to the PC during the data transfer. 

The power supply of the Mobile-Link 2 is ensured by an inte-
grated,  rechargeable  lithium-ion  battery  with  a  charge  of 
1950

 mAh.  Due  to  its  technology,  it  exhibits  a  certain,  mini-

mum  level  of  self-discharge.  This  is  why  we  recommend 
checking  the  charge  of  the  battery  prior  to  using  the  device, 
and to recharge it if necessary. 

The battery can be charged via a computer by way of a USB 
cable or by way of the supplied power supply unit. 

3

 

FUNCTIONAL AND OPERATING ELEMENTS

 

3.1

 

Operating elements on the top 

The Cobra4 Mobile-Link 2 is equipped with various elements 
for  the  measurement  data  display,  operation,  and  status 
indication.  These  elements  are  explained  in  detail  in  the 
following sections (Fig. 2).  

 

1. 

ON/OFF switch  
For  switching  the  unit  on  and  off.  The  process  of 
switching  the  unit  on  or  off  is  confirmed  by  way  of  a 
sound  signal  (brief  beeping  sound).  The  unit  has  an 
automatic  switch-off  function  in  order  to  prevent  the 
battery  from  being  discharged:  If  no  measurement  is 
performed, the unit will be switched off ten minutes af-
ter the last actuation of a button. If the voltage falls be-
low  a  critical  level  during  the  measurement  data  re-
cording  process,  an  audible  alarm  will  be  issued  and 
the  unit  will  save  the  measurement  values  that  have 
been  recorded  up  to  this  moment.  Then,  the  unit  will 
switch off. 

 

2. 

Display   
Colour representation of the measurement values and 
selection elements for the menu navigation.  
 

3. 

LED

 Battery  

For  indicating  the  battery  charging  process.  The  LED 
lights when a power supply unit or USB cable is con-
nected.   
 

4. 

Navigation arrows  
For  selecting  a  specific  measurement 
value  in  the  case  of  multi-channel  sen-
sors and for the menu navigation.  

 

5. 

Confirmation key  
For  starting  and  stopping  the  measurement  data  re-
cording process and for the menu navigation. 

 

 

3.2

 

Sensor interface

 

The  front  of  the  unit  is  equipped  with  an  interface  via  which 
the  connection  to  a  corresponding  Cobra4  Sensor-Unit  is 
realised.  This  mechanically  secure  connection  is  made  by 
way of lock knobs and holes on/in both units (Fig. 3). 

 

 

Fig. 3:  Cobra4 Mobile-Link 2 

– front with sensor interface. The 

lock knob 

 can be inserted into the hole 

 of the cor-

responding counterpart. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 2: Cobra4 Mobile-Link 2 

– operating elements 

 

 

 

 

 

 

 

 

Summary of Contents for 12620-09

Page 1: ...nsor Setup 1 2 5 4 3 Datalogger Setup 2 1 5 4 4 Datalogger Files 2 2 5 4 5 Zero 3 5 4 6 Calibration 4 5 4 7 Setup Date Time 5 1 5 4 8 Setup Battery status 5 2 5 4 10 Setup Information 5 4 5 4 11 Setup...

Page 2: ...supply unit 3 FUNCTIONAL AND OPERATING ELEMENTS 3 1 Operating elements on the top The Cobra4 Mobile Link 2 is equipped with various elements for the measurement data display operation and status indi...

Page 3: ...nity of the unit After a complete shut down of the unit it must be switched off and on again by way of the ON OFF switch operating ele ment If the unit does not react keep the ON OFF switch pressed fo...

Page 4: ...performed up to three times 5 3 Measurement data recording process A measurement can be started and stopped by pressing the confirmation key The measurement data recording proc ess is indicated by a...

Page 5: ...The file name consists of the date and a running counter YYMMDDxx mli xx 00 99 Ensure that the date and time are set in the Cobra4 Mobile Link This can be checked and if needed changed in the Setup m...

Page 6: ...Unit Conductivity 12632 00 It enables the automatic temperature compensation of a pH or conductivity measuring channel e g T 1 with regard to a temperature input or the manual input of a known temper...

Page 7: ...e following Cobra4 Sen sor Units Cobra4 Sensor Unit Radioactivity 12665 00 It is used to change the counter tube voltage in order to measure the counter tube characteristics Gate time This setting opt...

Page 8: ...imer Counter 12651 00 5 4 3 Datalogger Setup 2 1 The following changes are possible Selection of the single value measurement mode by way of a switch This ensures that only one value will be re corded...

Page 9: ...u item enables the measurement values of the measuring channels to be manually reset to zero To do so the switches of the desired channels are set from off to on by way of the arrow keys Fig 20 You ca...

Page 10: ...played in the header The automatic rotation of the device display can be switched on and off Use the confirmation key in order to confirm a new setting 5 4 10 Setup Information 5 4 Here you can find g...

Page 11: ...es minutes and seconds This menu item can only be used in combination with a Mo bile Link 2 GPS 12620 20 and GPS activated See also chapter 5 4 9 Coordinates will not be displayed unless satellites ha...

Page 12: ...f the battery decreases strongly it is possible to change the battery Please note that damage resulting from a battery change are not covered by the warranty You can send the Mobile Link to the repair...

Page 13: ...Unit Energy 12656 00 Cobra4 Sensor Unit Forceplate 12661 00 Cobra4 Sensor Unit Radioactivity 12665 00 Cobra4 Sensor Unit Sound Level 12669 00 Cobra4 Sensor Unit Weather air pressure humidity temperatu...

Reviews: