14 Appendix: Error Message and Diagnostic Alarm
14.1 Error Messages when Writing Data Records
If parameterisation errors occur while writing the DS128, an error message is generated:
Error
No.
Hex
Parameter
Permissible Setting range
PM
mod
e
TO
mod
e
32
0x20
Acceleration
100 - 100000000
X
X
33
0x21
Start stop frequency
1 - 250000
X
-
34
0x22
Run frequency
1 - 250000
X
-
35
0x23
M0P frequency
1 - 250000
X
-
36
0x24
Stop current
0 - 35
X
X
37
0x25
Run current
1 - 35
X
X
38
0x26
Boost current
0 - 35
X
-
39
0x27
Step resolution
0 - 8
X
X
40
0x28
Current delay time
0 - 15
X
X
41
0x29
Function of inputs
0 - 3, each function may only be
assigned to one input
X
-
0 - 3, Reference is assigned to an
input
-
X
42
0x2A
Steps per revolution
4 - 128000
-
X
43
0x2B
Traversing range
0 - 2147483647 steps
X
-
44
0x2C
Reference frequency
1 - 125000
-
X