8 Service
In the case of a service order, please proceed as follows:
First try to identify the technical problem. Feel free to ask our support team for help. We are
pleased to assist you.
Removal of a INAM01 module or exchange of the APS power stage sub module:
- Switch off the
phyMOTION
™’s supply voltage
- Disconnect the supply voltage
- Cut the red seal tape and the black label tape carefully on the left and right edge of the
module/front panel which you want to remove. Don’t slide the blade between the front
panels by no means. When backfitting by our service the red seal tape is renewed.
- Please note the following before the removal, because up to four INAM modules are
connected with the I4XM indexer module by a ribbon cable on the rear of the module:
- First, loosen the front screws of all five modules (I4XM and INAM).
-
Then pull the I4XM module carefully out of the housing by the handle – proceed with the
four INAM modules as well.
- Replace the corresponding APS assembly of the INAM module by loosening/removal.
- Then, starting with the I4XM module slide the five modules carefully back into the guide
rail. If you have problems to push the module for the last half centimeter, move the
module to the front panel slightly to the left and to the right during sliding, so that the
connector pins contact the backplane socket.
- To send a module to phytron use ESD packaging only.
The INAM02 module can only be replaced in the phytron’s plant. For this, the entire
phyMOTION
TM
device must be sent.
Summary of Contents for phyMOTION INAM01.1
Page 10: ...Manual INAM01 INAM02 MA 1275 A004 EN 10...
Page 11: ...phytron 11 MA 1275 A004 EN 4 2 Declaration of Conformity Modules with Internal Supply INT...
Page 12: ...Manual INAM01 INAM02 MA 1275 A004 EN 12...
Page 25: ...phytron 25 MA 1275 A004 EN Fig 5 PE connection for 5 wire motor cable by the NETM01 module...
Page 34: ...Manual INAM01 INAM02 MA 1275 A004 EN 34...
Page 35: ...phytron 35 MA 1275 A004 EN Synchronisation Fig 7 Synchronisation wiring...