1.2.3 Interfaces and Bus Mode
The X5 Com communication interface is available with USB, RS 485(4-wire), RS 232, or
Ethernet layout. The following possibilities are accessible by interface:
•
Controller and motor parameter programming
•
Controller configuration by software
•
Online diagnostics for safe operation and easy maintenance
•
Test mode and status information
•
Firmware update
•
Controller communication via Ethernet
The MCC-2 can be programmed user-friendly by MiniLog-Comm for Windows (see manual
MiniLog-Comm).
1.2.4 REMOTE/LOCAL-Switch R/L
You can select the controller's operating mode with the REMOTE/LOCAL switch:
REMOTE:
The controller is connected to the PC via interface. In this operating mode,
programs edited by the customer can be transmitted from PC to controller
and back. In the REMOTE mode it is also possible to test single
instructions or to test the motor run using the MiniLog-Comm
communication software.
LOCAL:
When switching to LOCAL the stored program will be started.
The program should be stored in the auto start register.
a)
The program runs
without
connection to the PC.
b)
Program run
with
connection to an external computer:
The PC can be called by the sequential program in order to
exchange actual data.
1.2.5 Reset Push-Button
The Reset push-button above the REMOTE/LOCAL switch is mounted recessed in order
to inhibit accidential operation.
Reset cancels possibly error messages.
Delay time after end of Reset signal: about 3 sec.