phytron
47
MA 2107-A005 EN
Jumper positions
J1 Jumper position
Open-Collector controlling SLS-A
1 – 2
Auxiliary voltage for IXE
α
2 – 3
Basic position
Fig. 29: ST2 10-pin connector
Safety Instructions:
•
The G-MSX adaptor board must only be connected and put into service by
qualified and trained personnel.
•
Switch off the supply voltage before connecting or disconnecting the power
stage.
Danger of damage by electric arcing.
•
All connectors must only be plugged in or out when the supply voltage is
switched off.
•
The G-MSX adaptor board has to be mounted in a closed housing, protected
against accidental contact.
Danger of electric shock when touching non-isolated powered
components.
•
When mounting the board, 6 mm minimum space between board (welding
and component side) and other components or the housing is recommended.
The minimum space at the left, right, upper and lower side of the board is
1.6 mm.