Manual MSX
MINI
MA 2107-A005 EN
34
9 Outputs
Open-Collector-Darlington outputs insulated by means of optocoupler
I
max
= 20 mA, U
max
= 45 V, UCE
sat
at 20 mA < 0.6 V
Fig. 17: Output wiring diagram
If inductive loads (e. g. a relay, motor brake) are connected, a protective diode must be
mounted.
9.1
position
Basic
Output
This signal is generated when the internal ring counter passes through zero, after the unit
is switched on and after a reset.
Every …. is generated for the step resolution
4th control pulse
Full step
8th control pulse
Half step
16th control pulse
1/4-step
20th control pulse
1/5- step
40th control pulse
1/10- step
80th. control pulse
1/20- step
The basic position signal can be used in combination with a limit switch to determine the
machine's zero.
position
Basic
(ZERO SIGNAL) is displayed by the green LED on the MSX front panel.
Basic position is also signaled during switch-on, unless an error message.
Remark:
If the motor is not energized, the
position
Basic
signal is generated anyway.