phyCORE-TriCore Development Board
©
PHYTEC Meßtechnik GmbH 2009 L-730e_0
41
1.3.15
USB connector X12
Depending on the used phyCORE-module on the Development Board,
the USB connector X12 provides the following connection.
For the phyCORE-TC1130:
X12 enables the connection to the
TC1130 USB feature
For the phyCORE-TC1130 the following jumper settings are required:
Jumper Setting
Description
JP9
Open
Disconnect 5V from USB Bus
JP28
2+3
Table 26:
Jumper Configuration for X12 USB connector for
phyCORE-TC1130
For the phyCORE-TC1796:
X12 enables the connection to the
TC1796 onboard USB to UART
Bridge.
For the phyCORE-TC1796 the following jumper settings are required:
Jumper Setting
Description
JP9
Closed
configuration for phyCORE-TC1796 module
JP28
open
configuration for phyCORE-TC1796 module
Table 27:
Jumper Configuration for X12 USB connector for
phyCORE-TC1796
Caution:
USB to UART Bridge can not be used with the standard phyCORE
TC1796 module, due to the module HW-configuration.