phyCORE-LPC2292/94
46
©
PHYTEC Messtechnik GmbH 2006 L-658e_5
3.26
C210 CLKIN Configuration
Capacitor C210 is used to input an external clock signal. In default
settings the on-board quartz oscillator is used for generating the
microcontroller's clock speed (C210 not populated). As an alternative
an external clock signal can be connected to the controller pin XIN via
phyCORE connector pin X700A1. This requires removal of the
on-board quartz oscillator and populating C210 with a 100p/50V
capacitor.
Note:
Because of the oscillator properties, C210 should not be closed when
using the on-board quartz oscillator. This can have a negative effect on
the stability of the quartz oscillation!
If an external clock input via X700A1 is required, the on-board quartz
oscillator must be removed.
The following configurations are possible:
CLKIN Configuration
C210
Using the on-board crystal XT1
open*
Supply via external clock signal at phyCORE
connector pin X700A1
100p/50V capacitor
mounted
* = Default setting
Table 35:
C210 CLKIN Configuration
Summary of Contents for phyCORE-LPC2292/94
Page 12: ...phyCORE LPC2292 94 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 76: ...phyCORE LPC2292 94 64 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 80: ...phyCORE LPC2292 94 68 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 88: ...phyCORE LPC2292 94 76 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 132: ...phyCORE LPC2292 94 120 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 136: ...phyCORE LPC2292 94 124 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 142: ...phyCORE LPC2292 94 130 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 144: ...Published by PHYTEC Me technik GmbH 2006 Ordering No L 658e_5 Printed in Germany...