phyCORE-LPC2292/94
106
©
PHYTEC Meßtechnik GmbH 2006 L-658e_5
Caution:
When using the DB-9 plug P2B as second CAN interface, and the
CAN transceiver on the Carrier Board with galvanic separation, the
following jumper settings are not functional and could damage the
module:
Jumper
Setting
Description
JP30
closed
Pin 8 at P2B is connected with TxD1_ext
from the phyCORE-LPC2292/94
1 + 2
Pin 2 at P2B is connected with RxD1_ext
from the phyCORE-LPC2292/94
JP33
2 + 4
Pin 2 at P2B is connected with CAN_L2/RD2 from the
phyCORE-LPC2292/94
JP34
2 + 3
Pin 7 at P2B is connected with CAN_H2/TD2 from the
phyCORE-LPC2292/94
1 + 2
Input at opto-coupler U6 on the Carrier Board is
connected to P1.21 of the phyCORE-LPC2292/94
2 + 3
Input at opto-coupler U6 on the Carrier Board is
connected to A23 of the phyCORE-LPC2292/94
JP14
open
Input at opto-coupler U6 on the Carrier Board
not connected
1 + 2
Output at opto-coupler U7 on the Carrier Board is
connected to P1.20 of the phyCORE-LPC2292/94
2 + 3
Output at opto-coupler U7 on the Carrier Board is
connected to A20 of the phyCORE-LPC2292/94
JP15
open
Output at opto-coupler U7 on the Carrier Board
not connected
JP13
2 + 3
Supply voltage for CAN transceiver and opto-coupler
derived from local supply circuitry on the
phyCORE Carrier Board HD200
JP18
closed
CAN transceiver and opto-coupler on the Carrier
Board connected with local GND potential
JP29
open
No power supply via CAN bus
JP39
see
Incorrect CAN bus supply voltage reduction for CAN
circuitry
Table 66:
Improper Jumper Settings for the CAN Plug P2B (CAN Transceiver
on Carrier Board with Galvanic Separation)
Summary of Contents for phyCORE-LPC2292/94
Page 12: ...phyCORE LPC2292 94 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 76: ...phyCORE LPC2292 94 64 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 80: ...phyCORE LPC2292 94 68 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 88: ...phyCORE LPC2292 94 76 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 132: ...phyCORE LPC2292 94 120 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 136: ...phyCORE LPC2292 94 124 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 142: ...phyCORE LPC2292 94 130 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 144: ...Published by PHYTEC Me technik GmbH 2006 Ordering No L 658e_5 Printed in Germany...