phyCOREi.MX31
98
©
PHYTEC Messtechnik GmbH 2007 L-700e_0
13.5.16.2
Universal camera pin header (X8)
A 2 mm universal connector X8 can be used to adapt other camera types. It is possible to supply the
external side of the camera level shifter with a external supply (VCC_CAM_EXT on the connector). For
this, the jumper JP15 should be moved on the position 2-3. The pin-out of the connector is shown in the
table below:
Table 33: Universal camera pin header X8
P
IN
#
S
IGNAL
N
AME
D
ESCRIPTION
1A
VCC_CAM_EXT
External power supply
1B
VCC_CAM_EXT
External power supply
2A VCC_3V3
Power
supply
2B VCC_3V3
Power
supply
3A x_RESET_3V3
/Reset
3B
CAM1_SDA
SDA Quick Capture
4A
CAM1_SCL
SCL Quick Capture
4B
CAM1_GPIO
I²C address config
5A
CAM1_FV
Frame start
5B GND
Ground
6A
CAM1_LV
Line start
6B GND
Ground
7A
CAM1_DD9
Data 9
7B
CAM1_DD8
Data 8
8A
CAM1_DD7
Data 7
8B
CAM1_DD6
Data 6
9A
CAM1_DD5
Data 5
9B CAM1_DD4
Data
4
10A CAM1_DD3
Data
3
10B
CAM1_DD2
Data 2
11A CAM1_DD1
Data
1
11B CAM1_DD0
Data
0
12A GND
Ground
12B
CAM1_PCLK
Pixel clock input
13A GND
Ground
13B
CAM1_MCLK
Clock output
14A GND
Ground
14B x_SNAPSHOT
Snapshot
Summary of Contents for phyCORE-i.MX31
Page 9: ...Contents PHYTEC Messtechnik GmbH 2007 L 700e_0...
Page 10: ......
Page 55: ...Debug Interface X201 PHYTEC Messtechnik GmbH 2007 L 700e_0 45...
Page 57: ...Debug Interface X201 PHYTEC Messtechnik GmbH 2007 L 700e_0 47...
Page 86: ...phyCOREi MX31 On NOR Flash On NAND Flash 76 PHYTEC Messtechnik GmbH 2007 L 700e_0...
Page 90: ...phyCOREi MX31 80 PHYTEC Messtechnik GmbH 2007 L 700e_0 JP17 more info JP604 more info...
Page 128: ...phyCOREi MX31 118 PHYTEC Messtechnik GmbH 2007 L 700e_0 13 6 1 LCD 004 Physical Dimensions TBD...
Page 135: ...Published by PHYTEC Messtechnik GmbH 2007 Ordering No L 700e_0 Printed in Germany...