![Phytec phyCORE-167CR Hardware Manual Download Page 87](http://html1.mh-extra.com/html/phytec/phycore-167cr/phycore-167cr_hardware-manual_1554145087.webp)
The phyCORE-167CR/167CS on the phyCORE-Development Board
PHYTEC Meßtechnik GmbH 2002 L-527e_8
77
14.3.6
Second CAN Interface at Plug P2B
Plug P2B is the upper plug of the double DB-9 connector at P2. P2b
is connected to the second CAN interface (CAN1) of the
phyCORE-167CS via jumpers. This option is only available if the
phyCORE module is populated with the Infineon C167CS (order
option PCM-009-C1). Depending on the configuration of the CAN
transceivers and their power supply, the following three
configurations are possible:
1.
CAN transceiver populating the phyCORE-167CS is enabled and
the CAN signals from the module extend directly to plug P2B.
Jumper
Setting
Description
JP33
2 + 4
Pin 2 of the DB-9 plug P2B is connected to CAN-L1
from on-board transceiver on the phyCORE module
JP34
2 + 3
Pin 7 of the DB-9 plug P2B is connected to CAN-H1
from on-board transceiver on the phyCORE module
JP14
open
Input at opto-coupler U6 on the phyCORE
Development Board HD200 open
JP15
open
Output at opto-coupler U7 on the phyCORE
Development Board HD200 open
JP13
open
CAN transceiver and opto-coupler on the Development
Board disconnected from supply voltage
JP18
open
No GND potential at CAN transceiver and opto-coupler
on the phyCORE Development Board HD200
JP29
open
No power supply via CAN bus
Table 41:
Jumper Configuration for CAN Plug P2B using the CAN Transceiver
on the phyCORE-167CS
Pin 3:
GND (Development Board Ground)
Pin 7:
CAN-H0 (not galvanically separated)
Pin 2:
CAN-L0 (not galvanically separated)
Pin 6:
GND (Development Board Ground)
Figure 20:
Pin Assignment of the DB-9 Plug P2B (CAN Transceiver on
phyCORE-167CS, only with C167CS)
1
2
3
4
7
6
5
8
9
Summary of Contents for phyCORE-167CR
Page 10: ...phyCORE 167CR 167CS PHYTEC Me technik GmbH 2002 L 527e_8...
Page 24: ...phyCORE 167CR 167CS 14 PHYTEC Me technik GmbH 2002 L 527e_8...
Page 40: ...phyCORE 167CR 167CS 30 PHYTEC Me technik GmbH 2002 L 527e_8...
Page 50: ...phyCORE 167CR 167CS 40 PHYTEC Me technik GmbH 2002 L 527e_8...
Page 102: ...phyCORE 167CR 167CS 92 PHYTEC Me technik GmbH 2002 L 527e_8...
Page 112: ...phyCORE 167CR 167CS 102 PHYTEC Me technik GmbH 2002 L 527e_8...
Page 114: ...Published by PHYTEC Me technik GmbH 2002 Ordering No L 527e_8 Printed in Germany...