Physio Logic ProScan 016-660 Instructions Manual Download Page 1

Generated by : 

Jean-François Perron

Flat Size : 
Assembled Size : 

Projet : 
Item No. : 

 

Part No. : 

Colours : 
 

B/W 

CMYK 

Spots:

016-660 ProScan instructions EN rev2 0718

016-660

911-016660

20.6 x 14 cm (open). 

10.3 x 14 cm  

(folded).

016-660

Front cover is

 CMYK,

 inside is

 Black ink

 only.

Summary of Contents for ProScan 016-660

Page 1: ...erron Flat Size Assembled Size Projet Item No Part No Colours B W CMYK Spots 016 660 ProScan instructions EN rev2 0718 016 660 911 016660 20 6 x 14 cm open 10 3 x 14 cm folded 016 660 Front cover is C...

Page 2: ......

Page 3: ...uration and menu functions 7 Choosing the temperature unit of measure Audio alert set up Choice of default display mode body or surface temperature How to calibrate the thermometer Audio ON OFF Exitin...

Page 4: ...mmable alerts 3 languages silent mode for taking temperature when child is sleeping Large backlit screen for nighttime readings 3 colour fever alerts Audio alerts signal peak temperature and fever Sto...

Page 5: ...in an instant As with any thermometer it is essential to use the ProScanTM Non Contact properly to ensure accurate temperatures Please read these instructions carefully before using this product and...

Page 6: ...artery As this artery is quite close to the surface of the forehead skin it allows precise reading of temperature This artery is linked to the heart by the carotid artery which is directly linked to...

Page 7: ...our fingers Clean the glass with a cotton swab lightly moistened with 95 alcohol Never use abrasive cleaning agents Never use rechargeable batteries Remove the batteries when thermometer is not used f...

Page 8: ...ond half of the cycle and at the early stages of pregnancy When sitting body temperature is lower by about 0 3 C to 0 4 C then when standing Age Range Normal body Fever High Fever Application Temperat...

Page 9: ...ND MENU FUNCTIONS Choosing the Temperature Unit of Measure Note ProScanTM Non Contact default is C 2 Select for C or for F 3 Confirm by pressing on the PROG button 1 Press on the PROG button for 3 sec...

Page 10: ...alerts threshold default settings are changed only the audio alerts will be pertinent not the colour alerts 1 Press on the PROG button for 3 seconds the screen displays F1 2 Press once more on the PR...

Page 11: ...ct 0 by pressing on the button to choose the BODY TEMP mode as default Select 1 by pressing on the button to choose the SURFACE TEMP mode as the default 4 Confirm by pressing on the PROG button Choice...

Page 12: ...o not modify this setting Each time there is a significant change in the ambient temperature due to a change in environment allow the ProScanTM Non Contact to adapt to the new ambient temperature for...

Page 13: ...0 by pressing on the button to power off the default audio feature Select 1 by pressing on the button to power on the audio as your default 4 Confirm by pressing on the PROG button Exiting the setting...

Page 14: ...on the button 3 Press on the button for review Note The number indicated when changing from one reading to another corresponds to the number of readings 4 To exit data memory press the measure key Th...

Page 15: ...ture of the room 4 By pressing the FR ENG ESP button you can change the language from French to English to Spanish or turn off the language function The default language setting is English CHANGING BA...

Page 16: ...ture reading is 38 C 100 4 F or higher you will hear 5 beeps and the LCD backlight colour will turn red which means that you have a high fever If the temperature reading is between 37 4 C 37 9 C 99 3...

Page 17: ...9 C 89 6 F 109 2 F In Surface mode 0 C 60 C 32 F 140 F In Air mode 0 C 40 C 32 F 104 F Precision Note The ProScanTM Non Contact Infrared Thermometer can take temperature readings below 32 C or above...

Page 18: ...mperature is superior to 40 C 104 F in Air mode Instructions 1 Turn the unit off for 15 60 seconds and then turn on again 2 Retake temperature using proper technique 3 cm 5 cm 1 2 2 and proper setting...

Page 19: ......

Page 20: ...ured and printed in China for Fabriqu et imprim en Chine pour A M G Medical Inc Montreal QC H4T 1V5 1 800 363 2381 Distributed in the USA by Distribu aux U par AMG Medical Inc West Chazy NY 12992 1 88...

Reviews: